Removal Of The Electrical Box - Daikin SUPER MULTI NX G Series Service Manual

Table of Contents

Advertisement

Outdoor Unit – 3MXS24JVJU / 4MXS32GVJU
2.2

Removal of the Electrical Box

Procedure
Step
1
Remove the 2 screws to
detach the grounds.
2
Disconnect the connector
for the fan motor [S70].
3
Release the fan motor
lead wire.
193
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
(R10396)
[S70]
(R6414)
(R10397)
(R6414)
SiUS12-928