SiUS12-928_A
5.23 Radiation Fin Temperature Rise
L4
Remote
Controller
Display
Outdoor Unit LED
A
Display
Method of
A radiation fin temperature rise is detected by checking the radiation fin temperature with the
Malfunction
compressor on.
Detection
The radiation fin temperature with the compressor on is above
Malfunction
The error is cleared when the temperature drops below
Decision
Conditions
18 class
24/32 class
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 60 minutes without any other error
Defective outdoor unit fan
Supposed
Short circuit
Causes
Defective fin thermistor
Disconnection of connector
Defective outdoor unit PCB
Silicon grease is not applied properly on the radiation fin after replacing the outdoor unit PCB.
Service Diagnosis
1
2
3
4
90°C (194°F)
105°C (221°F)
.
85°C (185°F)
97°C (207°F)
Troubleshooting
.
138