Appendix A • Unloaders
Table A-16. Type 16 Unloader - Cylinders: 8
Unloading Percentage: 13%, 38%, 63%
Unloading - Single cylinder on Unloader Output #1 *
% Load
Compressor Start Output
0 (OFF)
37
62
87
100
Table A-17. Type 17 Unloader - Cylinders: 6
Unloading Percentage: 33%, 50%, 66%
Unloading - Single cylinder on Unloader Output #1 *
% Load Compressor Start Output
0 (OFF)
0
33
1
50
1
66
1
100
1
Table A-18. Type 18 Unloader - Cylinders: 5
Unloading Percentage: 40%, 60% | Single cylinder on Unloader Output #1 *
% Load Compressor Start Output
0 (OFF)
40
60
100
* 0 = output OFF
1 = output ON
A – 6
Unloader Output #1
(single cylinder)
0
1
1
1
1
Unloader Output #1
(single cylinder)
0
0
1
0
0
Unloader Output #1
(single cylinder)
0
1
1
1
MicroVission Controller • Operation and Service Manual • Emerson • 35391MV 1.3
Unloader
Output #2
(double cylinder)
0
0
1
1
1
0
1
0
0
0
Unloader Output #2
(double cylinder)
0
1
0
0
0
Unloader Output #2
(double cylinder)
0
1
0
0
Unloader
Output #3
(double cylinder)
0
1
1
0
0
Unloader Output #3
(double cylinder)
0
1
1
1
0
% Unload
0
100
1
60
1
40
0
0
% Unload
100
63
38
13
0
% Unload
100
66
50
33
0