Kyocera ECOSYS MA4500fx Operation Manual page 322

Hide thumbs Also See for ECOSYS MA4500fx:
Table of Contents

Advertisement

Setup and Registration (System Menu) > System Menu
Item
WeeklyTimer Set.
Weekly Timer
Schedule
Retry Settings
Limited Retries
Retry Times
Retry Interval
Power Off Rule (models for
Europe)
Power Off Timer (models for
Europe)
Auto Err. Clear
Err. Clear Timer
Unusable Time
*3
Ping Timeout
*1 When the optional Network Interface Kit is installed, this is not displayed.
*2 Displayed only when the optional Card Authentication Kit is activated.
*3 Only on products with the fax function installed.
*4 Displayed only when the optional Network Interface Kit is installed.
Configure settings for switching the machine to OFF and waking it automatically at a
specified time for each day of the week.
Select whether to use Weekly Timer.
Value: Off, On
Specify the time for each day of the week at which the machine turns OFF.
Select whether to limit the numbers of retries for turning OFF this machine.
Value: On, Off
If you select [On] for Limited Retries, set the number of retries for turning OFF this
machine.
Value: 0 to 10 times
Set the retry interval.
Use [-] / [+] to enter a number.
Value: 10 to 60 seconds (increments of 10 seconds)
Select whether or not the machine enters Power Off mode for the following function.
Select [On] to set the Power Off mode.
Network
*3
FAX
USB Cable
USB Host
*4
NIC
NOTE
Even when any of the functions is set to [On], if [FAX] is set to [Off], the machine does not
enter Power Off Mode.
Even when [Network] or [USB Cable] is set to [Off], if the machine does not
communicate with the other devices, the machine will enter Power Off Mode.
Select whether to turn off the power automatically after a period of inactivity.
Value: 1 hour, 2 hours, 3 hours, 4 hours, 5 hours, 6 hours, 9 hours, 12 hours, 1 day, 2
days, 3 days, 4 days, 5 days, 6 days, 1 week
If an error occurs during processing, processing stops to wait for the next step to be
taken by the user. In the Auto Error Clear mode, automatically clear the error after a set
amount of time elapses.
Value: Off, On
If you select [On] for Auto Error Clear, set the amount of time to wait before automatically
clearing errors.
Value: 5 to 495 seconds (in 5 second increments)
NOTE
This function is displayed when [Auto Err. Clear] is set to [On].
FAX Operation Guide
Set the time until timeout occurs when [Ping] is executed in "System/Network".
Value: 1 to 30 seconds (in 1 second increments)
8-36
Description

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Ecosys ma4500x

Table of Contents