ALARM
Configures the alarm image transmission.
OFF
Disables the alarm image transmission.
ON
Enables the alarm image transmission.
SCHEDULE
Sends the alarm image only during the scheduled time.
CAMERA ID
This is inserted to the file name of the alarm image. It is also used as the name of the folder created on the
server.
You cannot use the following letters for CAMERA ID:
" ' " (single quotation), " " " (double quotation), "\" (backslash), "/" (slash), "<", ">", "?", "|", "*",
":" (colon) and ";" (semicolon).
If the CAMERA ID is not configured, "sanyo" and "alarm" are substituted as the file name and folder
name respectively.
OVERWRITE
Configures whether or not to overwrite file data transmitted to the FTP server.
OFF
Stores all files without conducting overwrite.
(date and time information is displayed in the file name)
ON
Overwrites.
(date and time information is not displayed in the file name)
Configures the image format used for alarm image transmission.
2
RESOLUTION
PICTURE QUALITY
Select the [BUFFER SIZE] option for specifying the buffering capacity for recording each alarm image.
3
According to the value you select, perform the following settings:
One alarm image set containing both the pre- and post-alarm images is stored in the camera, and then the
alarm image set is transferred one by one to the FTP server.
PRE/POST
Configures the recording capacity ratio between the pre- and post-alarm image recordings.
RATE
Configures the recording rate for the alarm image.
Depending on the shooting conditions, the number of images that are transferred will differ.
When the alarm is detected, only the post-alarm images will be transferred to the FTP server at the interval
you specified in the [TX RATE] setting.
Transfer may not end within the set time because communication speed may differ depending on the
network or FTP server environment.
DURATION
Specifies the duration of each alarm image to transfer (During this duration, no other alarms can be
processed for transferring the alarm image).
TX RATE
Configures the interval for transferring the alarm image (Select a value shorter than the [DURATION] setting).
Configures the operating conditions and camera ID for timer transmission.
When timer transmission is configured, one image at a time is automatically transmitted at the interval that was
set in [TX RATE].
TIMER
Specifies the preferences for image transmission using the timer.