4-10 PAPER SIDE SENSOR ADJUSTMENT
This is for adjusting the sensitivity of the PAPER SIDE SENSOR, which is for detecting the width of the
media. If it is not adjusted, media width could not be detected correctly.
Remove the Right Cover and Right Top Cover.
1
Open the Front Cover and move the Head Carriage leftwards
2
to the position where it is not above the Capping Unit.
Remove the Head Carriage Cover.
3
Lock the Head Carriage.
The Head Carriage Cover has six screws.
(Referential Time : 5min.)
Right Cover
4-43
Right Top Cover
Head Carriage Cover