MOTOR MENU
SERVO LOCK
MOTOR MENU
G-ENC. CHECK
SERVICE MENU
HEATER MENU
HEATER MENU
SVC. MODE HEAT.
HEATER MENU
HEATER ADJUST
HEATER MENU
PREHEAT TEMP.
HEATER MENU
HEAT TIMEOUT
HEATER MENU
HEATER CHECK
HEATER MENU
FEED FOR DRY L
SERVICE MENU
SYSTEM SWITCH
SYSTEM SWITCH
PAGE1
SYSTEM SWITCH
PAGE16
SERVICE MENU
HISTORY MENU
HISTORY MENU
MOTOR GROUP
In History Menu, the parameters are separated in groups
by categories. The parameters can be displayed or cleared
by selecting the group.
REPORT
SERVICE MENU
REPORT
ALL
SERVO LOCK
S:
100
SERVO LOCK
F:
240
20
G-ENC. CHECK
COMPLETED
SVC.MODE HEAT.
STOP
>
STOP
HEATER ADJUST
PRINT
HEATER ADJUST
DRYER
PREHEAT TEMP.
30 C
30 C
HEAT TIMEOUT
20min
30min
PRINT
_ 25 C
DRYER
25 C
This is for checking the heaters and thermistors.
While in this menu, it shows ON/OFF status and the temperatures read from the thermistors of Print heater and Dryer. [
are for selecting the heater or dryer and [ENTER] key is for turning ON/OFF the selected heater or dryer. "ON/OFF" mentioned here only
means to power on or off manually, and not to control the temperature. Be aware that the temperature keeps rising while it is ON. It turns off
automatically when exiting the menu.
Check if the temperature rises when the heater or dryer is ON and also if the temperature decreases to the room temperature when it is OFF.
The temperature is displayed in Celsius only.
FEED FOR DRY L
250mm  300mm
PAGE1
00000000
PAGE16
00000000
MOTOR HOURS F
7 hours
All the reports such as Sytem report, service report, history report,
ink cartridge IC report can be printed at once.
Use the sheet which print width is over 610mm(24inch).
The report printed area is horizontally long as 610mm width and 200mm length.
4-8
Servo Motor : LOCKED
This is for checking whether Servo Motor can be locked
SERVO LOCK
properly. While in this menu, Servo Motor is free. When
the Carriages are moved by hands, the displayed values
F:
0
0
* 
change as long as the feed-back is proper.
Servo Motor can be locked by pressing [ENTER] key.
When it is locked while the motor is in pause, the power
Servo Motor : FREE
is controlled normally.
As for [F(Feed direction)], the value displayed on the left
SERVO LOCK
changes by Grid Encoder, and the right changes by Motor
F:
0
0
Encoder.
This is for checking whether the Grit Encoder functions normally.
Be careful with the Feed Motor which drives as executing this
menu.
The heater does not operate when the machine is started in Service Mode.
Set [START] here when the heater needs to be on. [START] is canceled once the
Sub Power is turned off and the setting is back to [STOP] when entering the
Service Mode next time.
PRINT
This is for setting the offset of heater temperature.
0
0
The heater is controlled with this offset value added
to the temperature displayed on the LCD.
Range: -5 to +5
DRYER
0
0
This is for setting the heater temperature for [PREHEATING] under the
[HEATER MENU] in the User Menu.
Range: 20 to 40 C
Default: 30 C
This is for setting the time to show the confirmation message when controlling
heater temperature before printing. It shows the message of
[HEATING TIMEOUT CONTINUE?] when the temperature controll is not completed
at the specified timing when controlling the heater temperature before printing.
Range: OFF, 10 to 30 min (by 10 min)
This is for setting the amount of feed of media after printing when [FEED FOR DRY] and
[OPTION DRYER] under the [HEATER MENU] in the User Menu is "ENABLE".
This is for setting the system switch from page 1 to 16.
Each bit can be selected by [
] and [
] keys and switched by [
Press [ENTER] key to save the settings.
The rightmost positioned bit on each page is shown as bit 1,the leftmost positioned is
shown as bit 8.
On each page, [ENTER] key is disable if the cursor is at the rightmost position.
PAGE1
00000000
Page
Bit
Contents
Aqueous Ink Type
1: It enables to select aqueous ink type.
1
Third Party Aqueous
1: It enables to increase the frequency of ink
2
Ink Mode
evacuation when aqueous ink type is selected.
Setting of Ink Empty
1: It enables to cancel the empty state just by reading the
3
Solution
empty sensor without cartridge removal and insertion.
4
16
5
6
7
8
※The default value of system switch for all pages is 0 (zero).
MOTOR HOURS F
CLEAR
CATEGORIES: MOTOR GROUP / HEAD GROUP / MAINTE GROUP /
WIPE GROUP / PRINT GROUP / CUTTING GROUP /
INK GROUP / HEATER GROUP / ERROR GROUP /
SYSTEM
Default: 0
Default: 20 min
] and [
] keys
] and [
] keys.
Revised 2
Meanings
Default
0
0
0
0
0
0
0
0

Hide quick links: