Check Hydraulic Fluid

The hydraulic system is designed to operate on anti–
wear hydraulic fluid. The machines reservoir is filled at
the factory with approximately 12 U.S. quarts (11.4
liters) of Mobil 424 hydraulic fluid. Check level of hy-
draulic fluid before engine is first started and daily
thereafter.
1. Position machine on a level surface, raise the imple­
ment, and stop the engine.
2. Unscrew dipstick cap from the filler neck and wipe it
with a clean rag. Screw dipstick cap finger tight onto filler
neck. Unscrew the dipstick and check level of oil. If level
is not up to FULL mark on dipstick, add enough oil to
raise level to mark. DO NOT OVERFILL.
3. Screw dipstick filler cap finger–tight onto filler neck.
4. Lower the implement.
The following fluids are recommended for use:
ISO type 46/68 anti–wear hydraulic fluid
Mobil
Amoco
International Harvester
Texaco
Shell
Union OIl
Chevron
BP Oil
Boron OIl
Exxon
Conoco
Kendall
Phillips
Note: The fluids within this group are interchangeable.
IMPORTANT: Do Not Use Biodegradable Hydraulic
Fluid.
IMPORTANT: Use only types of hydraulic fluids spe-
cified. Other fluids could cause system damage.
Note: A red dye additive for detecting leaks in the hy­
draulic system is available in 2/3 oz. bottles. One bottle
is sufficient for 4–6 gal. (15 – 23 liters) of hydraulic fluid.
Order Part No. 44–2500 from your Authorized Toro Dis­
tributor
Hydraulic System
Mobil Fluid 424
Amoco 1000
Hy–Tran
TDH
Donax TD
Hydraulic/Tractor Fluid
Tractor Hydraulic Fluid
BP HYD TF
Eldoran UTH
Torque Fluid
Power–Tran 3
Hyken 052
HG Fluid
Page 5 – 22
1
Figure 29
1. Dipstick cap
Groundsmaster 3000/3000–D

Advertisement

loading

This manual is also suitable for:

Groundsmaster 3000-d