Change Engine Oil and Filter

Change oil and filter initially after the first 50 hours of op­
eration, thereafter change oil and filter every 100 hours.
1. Remove drain plug (Fig. 20) and let oil flow into drain
pan. When oil stops, install drain plug and new plug seal,
Part No. 74–7850.
2. Remove oil filter (Fig. 21). Apply a light coat of clean
oil to the new filter seal before screwing it on. DO NOT
OVER–TIGHTEN.
3. Add 15W–40 CE oil to crankcase. Capacity is 4.75
quarts with filter.
Peugeot TUD5 Engine
Page 4 – 10
1
Figure 20
1. Drain Plug
Figure 21
1. Oil Filter