Glow Plug Indicator Light
This light comes on when the glow control relay supplies
power to the glow plugs.
1. Disconnect wire clip and pin connector (pins 1 to 7)
from the pre/post heat relay.
2. Jumper from post # 8 (brass) on the glow control
relay to female receptor # 5 (green wire) on the pin con­
nector.
3. The light should come on. Remove jumper from
relay post and pin connector.
4. Connect pin connector and wire clip to the glow con­
trol relay.
Groundsmaster 3000/3000–D
A
Page 6 – 27
BACK OF GAUGE
A
F
B
E
B
C
D
E
F
Figure 47
SCHEMATIC
Figure 48