Enter a Maintenance programming session, reenable the system, and
press ® to exit.
Once the enabling is complete, the Administration Terminal will display
one of the following:
— a Config warning message
— System online
— a Config failure message
14.
Follow the instructions described in the paragraph that relates to the
message displayed.
a. A configuration warning message is normal, and is accompanied by
two options, RESET and RESUME . If M1 programming and rewiring
are complete, press RESUME .
b. System online appears if the M1 reprogramming and rewiring has
been into a new IPE Module and the cards are occupying exactly the
same slots as in the previous module. No action is required; proceed
to step 19.
c. The configuration failure message indicates that the cards have not
been installed correctly (that is, in their original order). Repeat steps
9 through 12.
15.
After pressing RESUME , you will see System startup, followed by
System online . If Base Stations have not been properly reconnected
to the new card slot and TCM device positions, a
Re-Eval required message displays. Follow these steps:
a. Clear the alarm message (see "Responding to event and alarm
messages" on page 139).
b. Rewire as necessary.
c. Restart the system.
Note: Auto Administration does not report missing Base Stations,
only those that have been relocated to a different address. Even
if the Re-Eval required message does not display, it is
important to proceed with the next two verification steps.
Meridian Companion Installation and Maintenance Guide
Maintenance Page 153 of 206