Cleaning
Body and Grilles:
Clean the panels of the body with a cloth dampened in
lukewarm water.
Remove the drip tray and cup holder grille and wash
with hot water.
Filters and Filter Holders:
Wash the filters and filter holders on a daily and
weekly basis, as indicated in para. 7.6.2.
Perform the cleaning operations on a daily basis as
indicated in para. 7.6.4 a pagina 37
Steam nozzle:
Keep the nozzle clean at all times using a cloth
dampened in lukewarm water.
Check and clean the nozzle tips, by clearing the steam
outlet holes with a small needle.
Wash these on a weekly basis, as indicated in para.
7.6.4 a pagina 37.
Dispensing group:
Internally clean the group on a weekly basis, as
indicated in para. 7.6.4.
Grinder-dispenser and Hopper:
Clean the hopper and the dispenser inside and out
with a cloth dampened with warm water.
When finished, dry all parts thoroughly.

Cleaning the filters and filter holders

7.6.2
Caution: only immerse the filter holder cup in
water and try not to get the handle wet.
The cleaner must be diluted in cold water in the
doses indicated on the package (see the manufacturer).
Daily:
• Soak the filter and filter
holder
in
hot
water
overnight so that the
fatty coffee deposits can
dissolve.
• Rinse everything in cold
water.
Weekly:
• Use a screwdriver to detach the filter from the filter holder.
• Soak the filter and filter holder in warm water with a
suitable cleaner for 10 minutes.
• Rinse everything in cold water.
User MANUAL
7.6.3

Washing the dispensing group

Wash the dispensing groups on a daily basis:
• Remove the filter from the filter holder and fit a blind filter
(see the standard supplied parts);
• pour the specific cleaner into the filter holder with the
X
blind filter and hook it to the dispensing group;
X
X
X
X
• carry out several dispensing cycles until the water comes
out clean;
• remove the filter holder from the group and carry out at
least one dispensing cycle in order to eliminate any clean-
er residues;
X
X
• remove the blind filter from the filter holder and replace it
with the original one.
X
7.6.4
Cleaning the group shower screen,
shower screen containment ring
and filter holder
Daily
Clean the dispensing group and filter holder
shower screens with the supplied brush.
Thoroughly clean the inside of the coupling
ring and filter holder, as well as the edge
and the wings of the filter holder, so as to
eliminate any accumulated coffee residues.
Use the special brush supplied (see the Spare Parts
Catalogue).
Weekly
Clean the shower screen as follows:
• Remove the seal (1) by carefully
using a screwdriver to pry it open
(take care not to damage it).
• Remove the shower screen (2) and
wash it in hot water.
• Reposition the shower screen and
seal in its original housing.