2 analog factory setting inputs
Measurement range: 0 VDC to 78 V
Input resistance: 103 kΩ
Surge-proof up to 53 V
Reverse voltage protection up to -53 V
Tolerance: ± 1 % of measurement range end
value (at 25 °C)
Analog IN (reset)
1 analog input
Measurement range: 0 V
Input resistance: 103 kΩ
Sampling rate: 20 Hz
Surge-proof up to 36 V
Reverse voltage protection up to -36 V
Tolerance: ± 1 % of measurement range end
Terminal 30
value (at 25 °C)
Acceleration sensor
Gyro sensor / rate of
Tolerance: ≤3 % of measurement range end
rotation sensor
Sampling rate: 20 Hz
Temperature sensor

9.2.4 Protocols

Table 41: Protocols
Protocols
Layer 2
CANopen
J1939, OBDII
Customer-speci c
TCP
SDO client

9.2.5 Status indicators

Table 42: Status indicators
Status indicators
All model variants
DC
DC
to 78 V
DC
DC
DC
Yes
Yes
Yes
On request
Yes
Yes
2 RGB LEDs (ON / STATUS)
TFX INSTALLATION AND OPERATION MANUAL

9.3 Certi cation and quali cation

The device has been certi ed and quali ed according to the
valid standards and regulations.
For more information on the corresponding approval tests,
DC
please contact the support service. See chapter Service
and support.
We will send you an overview of national approvals
on request.
Please contact our support service. See chapter Service
and support.
DC
PROEMION GmbH hereby declares that the TFX radio
system complies with the 2014/53/EU directive.
The full text of the conformity declarations is available
here: https://conformity.proemion.com
E1
ECE Regulation No. 10 (version 5)
Approval number:
6046279-001