Operation
NOTICE
If it is connected with a USB cable, USB A-Micro USB A,
1.8 - 2 m cable, the device automatically starts in bootloader
mode. The LEDs do not light up.
In the USB-Controller eld in the Device Manager, the
device is shown as "STM Device in DFU Mode" .
3. Start the
Firmware Programmer software.
PROEMION
4. In the menu, click on
to the storage path for the rmware update (*.
5. Select the rmware update (*.
O
button.
PEN
6. In the list in the
C
OMMUNI CATION
interface C
ONNE CTION VIA
7. In the list in the
D
EVI CE
8. Click on the S
F
TART
IRMWARE
9. Wait until the update is nished.
NOTICE
Device defect due to power failure.
Destroyed le system on the device. Repair by
PROEMION necessary.
Do not disconnect the device from the power supply until
the process has been completed.
During the rmware update, the LEDs light up green
in the same sequence.
In the eld F
D
IRMWARE
F
D
IRMWARE
OWNLOA DE D
rmware update is complete.
40
TFX INSTALLATION AND OPERATION MANUAL
F
> O
C
+O and navigate
ILE
PEN
TRL
F
B
) and click on the
W
IN
P
eld, select the
ATH
US B .
eld, select RM
D
.
EVI CE
D
button.
OWNLOA D
L
, the message
OWNLOA D
OG
S
appears when the
U CC ESSFULLY
10. Disconnect the device from the PC.
11. Disconnect using the main plug connector.
Switching the reset button on the main plug connector is
only necessary for models with an integrated battery.
The device is restarted.
After the restart, the device uses the updated
rmware version.
F
B
).
W
IN
You can nd a tutorial on how to install the rmware
to the device in the download area of our website.
See also chapter Service and support.
5.10

Over-the-air programming (OTAP)

5.10.1 OTAP introduction

TFX Over-the-air programming (OTAP) software is designed
for remotely downloading a new boot application le to
an Danfoss HFX hydraulic series (HFX) Programmable Logic
Controller (PLC). By following the standardized OTAP
process, users can update multiple machine HFX PLCs
without physically connecting to the controller, which saves
time and money.
Refer to the TFX – Over-the-air Programming USER
MANUAL for more information regarding OTAP .
5.10.2 OTAP – general process
In general, the OTAP process starts with a user uploading a
boot application le to the cloud using a web-based portal
provided by Proemion. Then, the Danfoss TFX telematics device
(TFX) uses a Global System for Mobile Communications
(GSM) module to wirelessly communicate with the portal and
download the boot application le. Next, the OTAP software
veri es HFX controller parameters and safe state status, and
the boot application le is internally processed by the TFX.
Then, the application le is sent to the HFX controller through
a CAN bus using a CAN calibration protocol (CCP). Finally,
the TFX downloads the boot application to the HFX controller,
and the HFX controller validates the download to conclude
the OTAP process.
OTAP process.
Refer to the TFX – Over-the-air Programming USER
MANUAL for more information regarding the Eaton-
standardized OTAP process.
6046279-001
March 2020
NOTICE
Figure 11 provides a summary of the
Fig 11. Summary of the OTAP process