Node Scan; Customizing The Demo Con Guration Le - Danfoss TFX Installation And Operation Manual

Table of Contents

Advertisement

Getting started
5. In the C
G
OMMUNI CATION
G
box.
ATEWAY
6. In the USB area, go to the V
select the assigned port of the of the TFX Support
Tool (e.g. COM5).
7. In the CAN B
R
AU D
ATE
250 KBIT/S.
8. Click on the O
-C
NLINE
HE CK
the connection.
If the connection is successful, the device information
is shown in the ID
AN D
S
and HW SW
V
TRING
9. Click on the OK button to save the settings.
You have completed the communication settings.

4.4.3 Node scan

Perform a node scan to check the connection.
NOTICE
Risk of property damage
Pay attention that the USB plug is correctly aligned to the
USB port on the computer before being plugged in and that
it is plugged in without using excessive force. Incorrect
alignment during connection or the use of excessive force
could cause damage to the USB port.
1. Connect the device to a PC. See chapter Connecting
the device to the PC
2. Start the Danfoss Con gurator software.
3. Click on T
> N
OOLS
ODE
Alternatively, you can click on the button in the toolbar.
16
TFX INSTALLATION AND OPERATION MANUAL
area, check the
ATEWAY
COM-P
list and
IRTUAL
ORT
list, select the baud rate
button to check
V
C
area in the ID
ERSION
ONTROL
elds
ERSION
S
in the menu.
CAN
The C
- N
OMMUNI CATION
window opens.
4. Click on the S
N
TART
ODE
The connected CAN devices with their CANopen Node-IDs,
product codes, and information on hardware and software
versions are displayed.
5. Select the device you want to con gure.
6. Click on the C
button.
LOSE
The Node-ID and the designation of the selected
device are shown in the toolbar.

4.4.4 Customizing the demo con guration le

NOTICE
Risk of property damage
Pay attention that the USB plug is correctly aligned to the
USB port on the computer before being plugged in and that
it is plugged in without using excessive force. Incorrect
alignment during connection or the use of excessive force
could cause damage to the USB port.
1. Connect the device to a PC. See chapter Connecting
the device to the PC.
2. Start the Danfoss Con gurator software.
3. Click on the arrow in the toolbar and select Demo
con guration les.
The O
DOD F
window opens.
PEN
ILE
4. Navigate to the right folder for your device and open
one of the les with the extension .DOD.
6046279-001
March 2020
S
I
ODE
CAN
NFORMATION
S
button.
CAN

Advertisement

Table of Contents
loading

This manual is also suitable for:

102ec77300a102ec77302a102ec77301a

Table of Contents