5.12

Factory reset

Performing a factory reset returns the device to the
original settings.
NOTICE
Severely restricted functions due to factory reset.
Repair by the supplier is necessary when there is an
incomplete con guration on the device.
Only trained personnel may carry out a factory reset.
NOTICE
Complete data loss due to factory reset.
All logged data is deleted from the device memory.
Back up your data before a factory reset.

5.12.1 Factory reset via OBW le or CAN

The following table provides an overview of the available
reset variants which can be triggered by an .obw le or the
CAN interface:

Table 36: Available reset variants

Function
Index
Sub-index
Revert to factory
con guration
0x1011 0x01
Delete all log
les
0x1011 0x62
Revert to
rmware
defaults remote 0x1011 0x63
Revert to
rmware
defaults plus
format remote 0x1011 0x64
Revert to
Firmware
Defaults Local
0x1011 0x65
INFORMATION
You can restore the factory con guration of the device using
object 0x1011, sub-index 0x01.
Description
The factory con guration is
restored. All logged data is
deleted.
All logged data is deleted.
The standard con guration of the
current rmware is restored. All
logged data is deleted.
CAN and mobile radio
parameters as well as the
factory con guration are
retained.
The standard con guration of
the current rmware is restored.
All logged data and the factory
con guration is deleted.
CAN and mobile radio
parameters are retained.
The standard con guration of the
current rmware is restored. All
logged data and parameters are
deleted.
The factory con guration
is retained.
TFX INSTALLATION AND OPERATION MANUAL
FACTORY RESET USING OBW FILE
To perform a factory reset using the OBW le, the OBW is
transferred to the device via the Data platform for remote
maintenance.
The OBW le writes the value 0x64616F6C to the CANopen
object index 0x1011 to trigger a speci c reset variant.
In the following example, the factory reset using the
sub-index 0x01 (revert to factory con guration) is shown:
: 0x1011, 0x01, 0x64616F6C; Revert to Factory Con guration
INFORMATION
For more information about the structure of an OBW le,
see chapter Con guring and reading o variables using the
Data platform.
1. Create a text le with the required value.
2. Save the text le (e.g. ResetAll.obw).
NOTICE
Please note that the le name must be precisely eight
characters long and that you must change the le extension
(*.obw) manually.
3. Go to the Portal website: https://portal.proemion.com/
4. Log in to the Portal with your administrator access
details (user name and password).
INFORMATION
If you do not have administrator access, contact your sales
or support representative. See chapter Service and support.
5. In the menu, click on
U
F
.
PLOA D
ILE
6. Select the corresponding machine from the
M
list.
A C HINE
7. Click on the C
F
HOOSE
OBW le.
8. Click on the U
button to load the OBW le to
PLOA D
the device.
6046279-001
March 2020
Operation
S
> D
> U
ERVI CE
EVI CE
PLOA D
button and select the
ILE
F
>
ILES
43