5.2 Logging mode

In logging mode, the device logs CAN messages, GNSS
data, and internal variables.
All logged data is saved to an internal, nonvolatile memory
and automatically sent to the Data platform when a
connection is active.
NOTICE
The internal nonvolatile memory has a capacity of 16 MB
and also stores con guration les. The maximum number
of les in the internal memory is 4,000, with a le size of
up to 1 KB. When the maximum number of 4,000 les is
reached, the oldest le will be overwritten every time a
new le is saved.
NOTICE
After the rst initialization, the device is automatically in
logging mode. If it is then switched to real-time mode, the
device remains in real-time mode after a restart.
NOTICE
Before you start logging data, check the device status in the
machine overview in the Portal.
The device must be in logging mode.
The colored squares in the machine overview indicate the
current status:
O
N
O
UM B ER
F
EW
B JE CTS AN D
O
eld, enter how many
B JE CTS
PD O is created.
TFX INSTALLATION AND OPERATION MANUAL
Constant blue = device is passive in real-time mode
Flashing blue = device is connected to a real-time
client software
Grayed out = device is o ine
Constant green = device is in le transfer / logging mode
Click on the current status to change it.

5.2.1 Con guring logging mode

1. Start DANFOSS Con gurator.
2. Choose F
> O
from the menu.
ILE
PEN
3. Open the con guration le you want.
4. In the object dictionary group
on the variable
D
EVI CE
5. In the D
M
( C
EVI CE
ODE
6. Click on the S
C
AVE
HANGES
Logging mode is enabled.
NOTICE
Con guring the D
-M
EVI CE
ODE
the device.
After manual switchover of the connection mode or after
an automatic switchover by a real-time client software, the
device remains in the mode last activated.
If required, con gure the automatic switchover of the
device. See chapter Con guring automatic switchover.

5.2.2 Con guring automatic switchover

The device features an automatic switchover function
between the logging and real-time modes. The automatic
switchover function is enabled as a standard.
You can enable the automatic switchover function and
6046279-001
March 2020
Operation
D
V
EVI CE
ARIA B LES
M
(C
).
ODE
ONFIGURE D
) eld, enter the value 0.
ONFIGURE D
button to save the change.
variable during rst startup of
, click
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

102ec77300a102ec77302a102ec77301a

Table of Contents