Download Print this page

Furuno FAR-2107 Series Service Manual page 568

Hide thumbs Also See for FAR-2107 Series:

Advertisement

PM-51 (S-band)
1. Frequency range
2. Input power
3. Power output (2nd pulse max output)
4. Power output (2nd pulse min output)
5. Steps levels (1st pulse to 2nd pulse)
6. POWER SUPPLY
1. Display unit
2. Processor unit
3. Antenna unit
Model
FAR-2137S(BB)
FAR-2167DS(BB)
FAR-2837S
FAR-2837SW
FAR-2137SW
4. Console
3020 to 3080 MHz
Min. -5 dBm, Max. +15 dBm
-15 dBm
-35 dBm
9.0 to 11.0 dB
24 VDC or 115/230 VAC, 1ø, 50/60 Hz
FAR-21x7: 24 VDC, 2.3 A; 100-230 VAC, 0.7A (100 V)
FAR-28x7: 24 VDC, 3.2 A; 100-230 VAC, 0.9 A (100 V)
440 VAC, 1 ø, 50/60 Hz with optional transformer RU-1803
FAR-2117/2817/2117-BB:
1
24VDC: 7.6A
/8.5A
220-230 VAC: 1.6A
FAR-2127/2827/2127-BB:
1
24 VDC: 8.8A
220-230 VAC: 1.8A
1:
Note:
24 rpm,
FAR-2827W:
3.2A (100-115 VAC), 1.6A (220-230 VAC)
FAR-2157/2157-BB/2167DS/2167DS-BB/2137S/2137S-BB/
2837S/2837SW:
3.0A (100-115 VAC), 1.5A (220-230 VAC)
X-band: 24 VDC, 4A, 200/220 VAC, 2A, 3ø, 50/60 Hz
S-band: 200/220/380/440 VAC 115/230 VAC, 1ø, 50 or 60 Hz
Antenna voltage input (100 kt)
200 VAC,
380 VAC,
ø3, 50 Hz,
ø3, 50 Hz,
220 VAC,
440 VAC,
ø3, 60 Hz
ø3, 60 Hz
3.0 A
1.5 A
3.0 A
1.5 A
3.0 A
1.5 A
3.0 A
1.5 A
3.0 A
1.5 A
115/230 VAC, 1ø, 50/60 Hz, 440 VAC, 1ø, 50/60 Hz with
optional transformer RU-1803
   
2
, 100-115 VAC: 2.6A
1
2
/1.7A
2
/9.7A
, 100-115 VAC: 3.0A
1
2
/1.9A
2:
42 rpm
220 VAC,
ø3, 50 Hz,
(HSC)
3.5 A
-
3.5 A
-
-
AP2-4
Appendix 2) Specifications
1
2
/3.0A
,
1
2
/3.4A
,
220 VAC,
440 VAC,
ø3, 60 Hz,
ø3, 60 Hz
(HSC)
(HSC)
3.5 A
1.7 A
-
-
3.5 A
1.7 A
-
-
-
-

Advertisement