19. Which chart card is read when 2 chart cards are inserted into CU-200?
- When two chart cards are inserted:
Priority is given to a card that includes Detailed Data of the chart and includes
the own ship position within the range of the chart.
- If both cards include Detailed Data of the chart, the card that was displayed
before updating is read.
Note:
- The FAR receives the chart data from CU-200 when the display is updated, for
example, the change of the range and others.
- Contents of Detailed Data: depth contour, place name, etc
20. Can the PSU-007 use commonly for different supply voltages?
See page.4-72.
As for the PSU-007, the supply voltages cannot use commonly. Four types of
the PSU-007 are available according to different types of gearboxes (antenna
motor). The models of thermal relays and their setting differ depending on the
motor power supply. The PSU-007 has a label showing a compatible gearbox on
its.
21. Is RPU-013 used commonly for X-band and S-band?
See page.4-69.
The RPU-013 cannot be used commonly for X-band and S-band. To distinguish
the type of RPU-013, check the name plate for the output power. It is indicated
the power type next to the power input terminal. And then, check the power
input terminal for indicating ship's main. There are 8 types of the PWR boards
according to the differences in ship's main and antenna speed, and 2 types of HV
boards for 10 kW and for 25 kW/30 kW according to the output power. The
initial setting includes the setting of MODEL.
Power type
100 VAC
220 VAC
24 VDC
12 VDC
PWR board (ANT: rpm)
03P9339A (24 rpm)
03P9339B (42 rpm)
03P9339C (24 rpm)
03P9339D (42 rpm)
03P9338C (24 rpm)
03P9338D (42 rpm)
03P9338A (24 rpm)
03P9338B (42 rpm)
FIL board
10 kW: HV-9017A
03P9341
- FAR-2x17
25/30 kW: HV-9017B
- FAR-2x27
- FAR-2827W
- FAR-2x37S
03P9352
- FAR-2837SW
8-5
TX-HV board
Q & A