4-5 Automatic FTC (AUTO RAIN)
This setting is made in FTC OFF/1/2/3/4 of the [PICTURE] box menu.
A
Target echo
The input signal A is subjected to the processing of moving average deviation. In this
processing, the range of the distance to be extracted is deviated in one sweep and signal
levels of respective distances extracted are averaged.
Averaged signals are multiplied by the coefficient K determined by the FTC setting. The
signal B is subtracted from the input signal A to create the signal C. The signal C is
STC-processed (curve of 1/Square of distance) and outputted. The FTC control knob is
used for adjusting the STC level. The effect of FTC is larger as the FTC setting value is
larger and as FTC VR is turned clockwise.
n Sweep
Fig. 7.3.18 Schematic diagram of moving average deviation processing
Moving average
deviations
Rain/snow echo
Fig. 7.3.17 Schematic diagram of AUTO FTC
Rang
-----
-----
-----
~
~
+
7-48
C
-
STC
Processing
x K
B
A
C=A-B
B
C
D
STC
-----
-----
Moving average
deviation Output
7.3 Processor Unit (RPU-013)
D
1
Range
2
FTC setting
4
3
2
1
OFF
FTC VR
(A/C RAIN VR)

Advertisement