Furuno FAR-2107 Series Service Manual page 378

Hide thumbs Also See for FAR-2107 Series:

Advertisement

4. The "FACTORY TEST" screen is displayed.
The checking items of the SIO are switched in sequence. If a port jumpered in Step 1
functions properly, "OK" is displayed. If not, "—" is displayed.
Test
Result
item
AIS
OK / -
HDG
OK / -
LOG
OK / -
NAV
OK / -
TRK
OK / -
RS-232C
OK / -
KEY IO
OK / -
RF IO
OK / -
1000->
ALARM
0100->
IO
0010->
0001
Test
speed
38.4
Loopback test of AIS port J611. In the test, characters of
kbps
"FAR2107" are sent. If they are received, it is judged as OK.
Characters of "FAR2107" are sent from the SERIAL I/F (TD)
38.4
J621 to the HDG port J605. If they are received, it is judged as
kbps
OK.
38.4
Characters of "FAR2107" are sent from the J621: SERIAL I/F
kbps
(TD) to the J607: LOG port.
38.4
Characters of "FAR2107" are sent from J619: ECDIS (TD) to
kbps
J606: NAVIGATOR. If they are received, it is judged as OK.
38.4
Loopback test of TRK port. In the test, characters of "AR2107F"
kbps
are sent. If they are received, it is judged as OK.
4.8
Loopback test of J601: RS-232C. In the test, characters of
kbps
"FAR2107" are sent. If they are received, it is judged as OK.
19.2
The command of the test mode is sent to the control unit. If the
kbps
program number comes back, it is judged as OK.
115.2
The command of the test mode is sent. If the program number
kbps
comes back, it is judged as OK.
During the test, the display changes in the order of
"1000->0100->0010->0001". This change is synchronized with
the J612: EXT ALARM output (ON/OFF).
In ALARM-4 alone, ON/OFF operations are opposite to those of
ALARM-1 to 3.
1000: ALARM-1 (#1-2), 0100: ALARM-2 (#3-4),
0010: ALARM-3 (#5-6), 0001: ALARM-4 (#7-8),
NOTE:
The polarity of ALARM-1 to 4 (ON/OFF) depends on the
setting of "[Menu] -> 3-> 6, 7, 8, 9-> 9: ALARM OUT
POLARITY".
The setting item is not available on the IMO and A types.
6-22
Table 6.2.3 Result in Loopback Test
Description
6.2 FACTORY TEST