CR23 (Input Over/Low-Voltage)
Check point
Main Inverter Output
R85
adjustment
Output Over voltage
R92
Protection adjustment
Output Over voltage
CR61
Protection detection
Inverter SW
R45
Frequency adjustment
Input Over/Low
CR23
Voltage detection
Input Over voltage
R21
Protection adjustment
TP6
P8 (Switching power input voltage)
R85
R21
Fig. 9.4.9 TX HV board
J3: Adjusts TX-HV voltage to 770 VDC.
J3: When TX-HV voltage is 810 to 830 VDC, adjusts to light
CR61.
J3: When TX HV voltage is 810 to 830 VDC, CR61 is light.
Adjusts to 70 + 5kHz at R45.
Checking point: TP6 - TP2(GND)
Over voltage protection: 141-147(100)/282-294(200) VAC
Low voltage protection: 88(100)/190(220) VAC or less
When the above voltages are detected, CR23 is light.
When the input voltage is 144(100)/288(220) VAC, adjusts to
light.
9-20
R92
CR61 (Output Over Voltage)
TP2
R45
Table 9.4.4 Check point of TX HV board