Download Print this page

Furuno FAR-2107 Series Service Manual page 299

Hide thumbs Also See for FAR-2107 Series:

Advertisement

2. Changing of IP address
Never change the IP address except for special types specified below.
If the IP address is improperly changed, the system may fail to work properly.
In order to allow the Inter switch function of the radar to work properly between
networks, it is required to set up the IP address specified to the network, subnet mask,
default gateway and destination. Connection should be one-to-one connection according
to the 100 Base-Tx. Detailed equipment and specifications are not described here.
The IP address can also be changed on CU-200. (Only one network.) It cannot be shared
among multiple networks.
Note that IP address of CU-200 can be rewrite, and the program versions of CU-200 are
0359209-01.02 or later.
IP: 172.31.3.6
FAR-2xx7
Series
Gateway:
RADAR NO.(ANT)
:1
IP ADDRESS
:172.31.3.6
SUBNET MASK
:255.255.0.0
GATEWAY
:172.31.3.254
DESTINATION
:192.168.1.1
Note 1: Changing the IP address of the radar
Procedure
1. Press the [Menu] key 5 times while holding down the [1] key to open the
"INITIALIZE" menu.
2. Select the radar number of the own radar in "INITIALIZE -> 4: INSTALLATION
-> 4: RADAR NO".
3. When the message "Completed!! Power on restart." is displayed, restart the power.
4. Press the [2], [3] and [4] keys in order while holding down the [1] key to call up the
"FACTORY" menu.
Router
Gateway:
172.31.3.254
192.168.1.254
RADAR NO.(ANT)
IP ADDRESS
SUBNET MASK
GATEWAY
DESTINATION
Note-2:
INS ADDRESS: Set to
the ECDIS IP adress
Fig. 4.4.14 Example of Network Connection
4-35
IP: 192.168.1.1
FAR-2xx7
Series
:2
:192.168.1.1
:255.255.0.0
:192.168.1.254
:172.31.3.6
4.4 Initialize Setting
Note-1:
The DESTINATION setting
has to set the IP address of
the other radar.