5.3.4 Perform tubingflush at shutdown

When to perform?
A tubing flush must be performed daily when shutting down.
Only use Mutoh water based textile cleaning liquid.
Only use the swabs from the Good shape kit.
Caps have to be flushed with cleaning liquid when shutting down the printer.
Do not move the position of the wiper arm (forwards / backwards) to prevent error generating
when head returns to the cap position.
Procedure:
Step 1 :
Perform a tubing flush (F4 in Menu 6/7)
Step 2 :
Press the F1 button. The pumps will start for cap 1-4-5-8
Step 3 :
Flush caps 1-4-5-8 with Mutoh water based textile cleaning liquid until the colour of the mousse in
the cap does not change anymore.
Step 4 :
Let the pumps run for 10 more seconds without adding anymore cleaning liquid.
Step 5 :
Press enter to stop the pumps
Step 6 :
Press the F2 Button. The pump will start for caps 2-3-6-7
Downloaded From ManualsPrinter.com Manuals