3. Select and left-click, in order, [Others], [Initial Setting]. In the pop-up window, se-
lect [Changeable].
4. Select [Others] from the System menu items, then select [Model], then select
[FSV-85-MK-2-70].
3.7

How to Register the Transducer Position

To display the distance which the transducer is protruded, the limit switch location
must be entered at the processor unit.
This setting requires the transducer to be protruded from a fully retracted position.
Make sure there is sufficient room for full protrusion.
1. Turn the FSV unit's power on.
2. Press the MENU/ESC key to display the main menu.
3. Select and left-click, in order, [Others], [Initial Setting]. In the pop-up window, se-
lect [Changeable].
4. Select [Hull Unit Setting].
5. Select [REG TD Position].
The following confirmation message appears.
Note: When the transducer position is already registered, the following message
appears. To re-register the transducer position, select [Next] the left click.
6. Confirm that transducer is retracted, then select [Next].
7. Confirm that the transducer can be protruded fully, then select [Next].
8. Check the safety and press the
9. When the transducer is at full protrusion, select [Next].
10. Press the
11. Select [Quit].
This item is defined as non-changeable
(Full-protrude) key to protrude the transducer.
(Retract) key to retract the transducer.
3. ADJUSTMENTS AND CHECKS
Caution
item. Are you sure to change it
changeable?
Changeable
Cancel
3-5