Furuno FSV-85-MARK-2 Installation Manual page 48

Color scanning sonar
Hide thumbs Also See for FSV-85-MARK-2:
Table of Contents

Advertisement

2. WIRING
DPYCYS-2.5 cable
Fabricate the cable as shown in the following figure.
Anti-corrosive
sheath
2.5.2
Input Voltage and Fuses
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC
and a 10 A fuse inserted in F601 and F602. For other voltages, change toggle switch
positions and fuses as shown below.
Input voltage and toggle switch
Input voltage
100 VAC
110 VAC
115 VAC
220 VAC
230 VAC
Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table
below.
Input Voltage (TB-B101)
100 VAC
110 VAC
115 VAC
220 VAC
230 VAC
2-14
140 mm
140 mm
35 mm
35 mm
30 mm
30 mm
vinyl sheath
Set armor in cable clamp
S603
S604
L
L
H
L
H
H
H
L
H
H
F601
20A
10A
WARNING
Use the correct fuse.
Use of a wrong fuse can result in
damage to the equipment.
Crimp-on lug FV2-4
(2 pcs. )
Default
S605
setting
L
L
L
H
H
Default
Default
F602
setting
-
20A
-
-
-
10A
Default
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsv-85 mark-2Fsv-8422-mk2Fsv-8423-mk2

Table of Contents