2. Fix the unit with four screws (M4) from under side of the desktop. (Supply the
screws locally. Be sure the screws are of a sufficient length for the thickness of
the desktop.)
1.10.3
Flush mount (option)
Use the optional flush mount kit (Type: FP03-09870, Code No.: 008-535-630) to
mount the sub control unit.
Name
Mounting plate
Hex nut
Wing screw
Pan head screw
1. Prepare a cutout in the mounting location referring to the outline drawing at the
back of this manual.
2. Set the unit to the cutout.
3. Attach the mounting plate to the unit with four screws from the rear side.
4. Screw the wing screw to each mounting plate and then insert hex bolt to each wing
screw.
5. Fasten each wing screw and then fasten the hex nuts.
Type
03-163-7531
100-306-261
M5
000-863-108
M5x40
000-162-682-10
M4x12
000-163-192-10
1. HOW TO INSTALL THE SYSTEM
Code No.
Qty
4
4
4
4
1-25