Furuno FSV-85-MARK-2 Installation Manual page 42

Color scanning sonar
Hide thumbs Also See for FSV-85-MARK-2:
Table of Contents

Advertisement

2. WIRING
LAN cable
Fabricate the LAN cable (DTIC5E350SLABVCVxxT, max 100 m), referring to the fol-
lowing figure. After fabricating the cable, attach the modular connector.
Note: This equipment only uses straight cables. Use a CAT5E LAN cable.
Processor Unit side
Armor
Cable jacket
Outer vinyl sheath
Transceiver Unit side
Armor
Cable jacket
Outer vinyl sheath
Expose inner vinyl sheath.
approx. 9 mm
Fold back drain wire and cut it,
leaving approx. 9 mm.
Using special crimping tool
MPT5-8AS (PANDUIT CORP.), crimp
the modular plug. Finally, check the
plug visually.
2-8
40 40
Inner vinyl sheath
600
600
540
540
Inner vinyl sheath
25 mm
Remove the inner vinyl sheath by
approx. 25 mm. Be careful not to
damage inner shield and cores.
approx. 11 mm
Straighten and flatten the cores
in colored order and cut them,
leaving approx. 11 mm.
Modular plug
Vinyl tape
35 35
Vinyl tape
approx. 9 mm
Fold back the shield, wrap it onto
the inner vinyl sheath and cut it,
leaving approx. 9 mm.
Drain wire
Insert the cable into the modular
plug so that the folded part of the
shield enters into the plug housing.
The drain wire should be located
on the tab side of the jack.
[Straight cable]
1 WHT/ORG
2 ORG
3 WHT/GRN
4 BLU
5 WHT/BLU
6 GRN
7 WHT/BRN
8 BRN
WHT/ORG 1
ORG 2
WHT/GRN 3
BLU 4
WHT/BLU 5
GRN 6
WHT/BRN 7
BRN 8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsv-85 mark-2Fsv-8422-mk2Fsv-8423-mk2

Table of Contents