Model
SAFETY INSTRUCTIONS ................................................................................................ i
SYSTEM CONFIGURATION .......................................................................................... iii
EQUIPMENT LISTS........................................................................................................ iv
1. HOW TO INSTALL THE SYSTEM ..........................................................................1-1
1.1 Hull Unit .............................................................................................................................1-1
1.2 Processor Unit ...................................................................................................................1-7
1.3 Control Unit ........................................................................................................................1-9
1.4 Transceiver Unit...............................................................................................................1-11
1.5 Transducer Cable Extension Kit .....................................................................................1-12
1.6 IF Unit ..............................................................................................................................1-13
1.7 Grounding the Equipment ................................................................................................1-13
1.8 Attachment Flange (option)..............................................................................................1-13
1.9 Attachment Kit (option) ....................................................................................................1-14
2. WIRING....................................................................................................................2-1
2.1 How to Use the Crimping Tool, Pin Extractor ....................................................................2-1
2.2 How to Connect Units ........................................................................................................2-2
2.3 Processor Unit ...................................................................................................................2-3
2.4 IF Unit ................................................................................................................................2-6
2.5 Control Unit and Remote Controller...................................................................................2-9
2.6 Transceiver Unit...............................................................................................................2-11
2.7 Transducer Cable Extension Kit .....................................................................................2-14
2.8 Control Box of Hull Unit....................................................................................................2-15
2.9 Input Voltage and Fuses ..................................................................................................2-16
3. ADJUSTMENTS AND CHECKS .............................................................................3-1
3.1 Hull Unit Check ..................................................................................................................3-1
3.2 How to Show the System Menu.........................................................................................3-3
3.3 How to Adjust the Heading ................................................................................................3-4
3.4 How to Configure the Own Ship Mark................................................................................3-6
3.5 Others Menu ......................................................................................................................3-7
APPENDIX 1 JIS CABLE GUIDE .............................................................................AP-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Advertisement

Table of Contents
loading

Summary of Contents for Furuno FSV-35

  • Page 1: Table Of Contents

    Installation Manual Color Scanning Sonar FSV-35/FSVB-35S Model SAFETY INSTRUCTIONS ....................i SYSTEM CONFIGURATION ..................iii EQUIPMENT LISTS......................iv 1. HOW TO INSTALL THE SYSTEM ................1-1 1.1 Hull Unit ..........................1-1 1.2 Processor Unit ........................1-7 1.3 Control Unit ........................1-9 1.4 Transceiver Unit.......................1-11 1.5 Transducer Cable Extension Kit ..................1-12...
  • Page 2 ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN A : JUL 2012 Printed in Japan All rights reserved. C2 : MAR . 24, 2015 Pub. No. IME-13330-C2 ( ETMI ) FSV-35/35S 0 0 0 1 7 5 7 9 1 1 2...
  • Page 3: Safety Instructions

    FURUNO will assume no responsibility for High voltage exists inside the equipment, any damage associated with improper and a residual charge remains in capacitors installation.
  • Page 4 SAFETY INSTRUCTIONS WARNING CAUTION If a steel tank is installed on a wooden Maximum speed while the transducer is or FRP vessel, take appropriate projected or being raised or lowered measures to prevent electrolytic is as below, to prevent damage to the corrosion.
  • Page 5: System Configuration

    SYSTEM CONFIGURATION Monitor Monitor USB device (mouse, etc.) Processor Unit FSV-3503 (FSV-35)/ Junction Box FI-5002 FSV-3503S (FSV-35S) 12-24 VDC NMEA IEC 61162-1 device NMEA IEC 61162-1 device Rectifier Speaker RU-1746B-2 Sub Control Unit 100/110/115/ FSV-853 220/230 VAC, φ , 50/60 Hz...
  • Page 6: Equipment Lists

    For FSV-35S Transceiver FSV-351 Hull Unit FSV-303 1200 mm stroke FSV-304 1600 mm stroke Installation Materi- CP10-06000 000-067-071 For FSV-35/35S, no Trans- ducer Cable Extension Kit CP10-06201 007-008-540 For Transceiver Unit CP10-07200 000-117-257 For Control Unit, w/CP10- 07201, CP03-33202 CP10-07300 000-017-123 For IF Unit, w/CP10-07301 (incl.
  • Page 7: How To Install The System

    HOW TO INSTALL THE SYSTEM Hull Unit Note 1: The control box on the hull unit contains a motion sensor. Handle the hull unit carefully. Note 2: Handle the transducer carefully. Rough handling will damage its sensitive components. 1.1.1 Installation considerations Decide the location of the hull unit through consultation with the dockyard and ship owner.
  • Page 8 1. HOW TO INSTALL THE SYSTEM • If the ambient temperature around the unit will be below 0°C, provide the sonar compartment with a heater to keep the temperature above 0°C. 1300 (52”) (26”) Compartment Note: After you mount the hull unit, be sure to install anti-vibration stays, referring to page 1-5.
  • Page 9 1. HOW TO INSTALL THE SYSTEM 1.1.2 Guideline for how to shorten the retraction tank Shorten the tank as necessary so that the transducer positions well below the keel when it is fully lowered. The following table provides guidelines for shortening the tank. Refer also to the retraction tank installation drawing at the back of this manual.
  • Page 10 1. HOW TO INSTALL THE SYSTEM 1.1.3 How to install the Hull Unit on the retraction tank Weld the retraction tank and allow sufficient time for cooling. Install the hull unit as fol- lows: Prepare the materials and tools as shown below. Name Remarks Screw wrench...
  • Page 11 1. HOW TO INSTALL THE SYSTEM Hex. nut Spring washer Flat washer Bow mark HULL UNIT FLANGE O-ring TANK FLANGE Flat washer Hex bolt Hex. nut O-ring Spring washer Flat washer Flat washer Spring washer O-ring Hex. nut Flat washer Retraction Stern side (7 places) Tank...
  • Page 12 1. HOW TO INSTALL THE SYSTEM WRONG INSTALLATION METHOD: Stay fixed to crossbeam on overhead Stay Eye-bolt CORRECT INSTALLATION METHOD: Stay installed horizontally HULL UNIT 90° Note: Reinforce the hull unit against vibration by extending stays to prevent the dam- age to the transducer from the vibration.
  • Page 13: Processor Unit

    1. HOW TO INSTALL THE SYSTEM Processor Unit 1.2.1 Installation considerations Follow the points below to select an installation location. • Mount the unit upright. • Locate the unit out of direct sunlight and away from heat sources because of heat that can build up inside the unit.
  • Page 14 1. HOW TO INSTALL THE SYSTEM Bulkhead installation 1. Mark locations for four self-tapping screws on the installation location. 2. Insert two self-tapping screws (6x30, supplied) at the top two screw holes, leaving approx. 5 mm of the screws exposed. 3.
  • Page 15: Control Unit

    1. HOW TO INSTALL THE SYSTEM Control Unit The control unit can be installed in a console (flush mount) or on a desktop (with KB fixture). Select a location considering the following points. • Select a location where the controls can be easily operated. •...
  • Page 16 1. HOW TO INSTALL THE SYSTEM 2. Make holes for four self-tapping screws (M5x20). 3. Peel the tape from the F mount gasket then attach the gasket to the rear of the control unit. 4. Connect a ground wire (1.25sq, local supply) between the ground terminal at the bottom of the unit and ship’s ground.
  • Page 17: Transceiver Unit

    1. HOW TO INSTALL THE SYSTEM Flush mount (option) Use the optional flush mount kit (Type: FP03-09870, Code No.: 008-535-630) to mount the sub control unit. Name Type Code No. Mounting plate 03-163-7531 100-306-261 Hex nut 000-863-108 Wing screw M5x40 000-162-682-10 Pan head screw M4x12...
  • Page 18: Transducer Cable Extension Kit

    1. HOW TO INSTALL THE SYSTEM Transducer Cable Extension Kit The transducer cable extension kit can extend the distance between the hull unit and transceiver unit. The kit is available in two versions: 5 m extension and 15 m exten- sion.
  • Page 19: If Unit

    1. HOW TO INSTALL THE SYSTEM IF Unit Refer to the outline drawing at the back of this manual for mounting dimensions. Fas- ten the unit with 5x20 self-tapping screws. If the unit is to be installed on a bulkhead, be sure that the location does not allow water to drip into the cable entrance.
  • Page 20: Attachment Kit (Option)

    1. HOW TO INSTALL THE SYSTEM Hex. bolt Flat washer Hull unit flange O-ring Flat washer Spring washer Hex. nut Attachment flange O-ring Retraction tank Flat washer Spring washer Hex. nut Note: Inscribe the bow mark to the attachment flange. Attachment Kit (option) The attachment kit permits use of the retraction tank for the CSH-20 series using the 1600 mm stroke transducer and hull unit FSV-243E/244E.
  • Page 21 1. HOW TO INSTALL THE SYSTEM 6. Coat the threads of the bolts with a slight amount of lithium grease to prevent scorching. Insert the bolts with washers from the retraction tank flange, and then put the flat washers and spring washers in this order from above. Fasten bolts with nuts.
  • Page 22 1. HOW TO INSTALL THE SYSTEM This page is intentionally left blank. 1-16...
  • Page 23: Wiring

    WIRING How to Use the Crimping Tool, Pin Extractor A special crimping tool is necessary for connection of wires to the contact pins of the 10P connector. The pin extractor removes the contact pin from the connector body. Crimping Tool Pin Extractor Contact Pin 06-1001-016...
  • Page 24: How To Connect Units

    2. WIRING How to Connect Units PROCESSOR UNIT FSV-3503 (FSV-35)/ FSV-3503S (FSV-35S) DVI-D/D LINK (5m /10 m) MONITOR (local supply) DPYC-6 12-24 VDC 19S1050 (3 m) SUB CONTROL UNIT USB cable FSV-853 (option) IF UNIT 10S2884 FSV-8502 5m/10m CONTROL UNIT...
  • Page 25: Processor Unit

    2. WIRING Processor Unit Connect the cables of other equipment at the rear of the processor unit. Transceiver Unit (FSV-351) External Monitor (SXGA) IF Unit IF Unit (FSV-8502) FR-FTPC-CY, (FSV-8502) DVI-D/D SINGLELINK, within 100 m 5 m or 10 m 10S2383, 3 m 10S1050, 3 m USB cable...
  • Page 26 2. WIRING LAN cable Fabricate the supplied LAN cable (FR-FTPC-CY, 10/20/30/50/100 m) as shown be- low. Cut the vinyl sheath and armor to the lengths shown below and attach the mod- ular connector. Armor Outer vinyl sheath Inner vinyl sheath Wrap vinyl tape 25mm approx.
  • Page 27 2. WIRING How to extend length of cable for external monitor If the distance from the control unit to the monitor is more than 10 m, follow the proce- dure below to lengthen the cable, up to 70 m. The video output is analog so use an analog monitor.
  • Page 28: If Unit

    The IF unit installs between the processor unit and the transceiver unit. Connect the cables according to the diagram inscribed on the shield cover of the IF unit. JIS cables and FURUNO cables are available for the connection. To connect the JIS cables, use the larger cable holes as shown below.
  • Page 29 Remove sheath Vinyl tape Braided shield Wrap braided shield around vinyl sheath. Cover braided shield with vinyl tape. Cable for FURUNO CIF1 equipment 45 mm Remove sheath Wrap braided shield around vinyl sheath. Cover braided shield with conductive fabric tape.
  • Page 30 2. WIRING How to connect external KP To synchronize transmission with external sonar, make the connections shown below. • Current drive KP output IF UNIT KP signal Sonar • Voltage drive (12 V) KP output IF UNIT KP signal Sonar •...
  • Page 31: Control Unit And Remote Controller

    2. WIRING Control Unit and Remote Controller Ground Connect a IV-1.25 sq ground wire (local supply) between the ground terminal on the control unit and the ship’s ground. How to connect the remote controller Connect the optional remote controller (FSV-854) as shown below. 1.
  • Page 32 2. WIRING 3. Connect the remote controller cable to J2 on the control unit and use the support plate to fix the cable. Panhead screw M4x12, 3 pcs. Fix at copper tape. Support plate Rear side of the control unit (cover removed) 4.
  • Page 33: Transceiver Unit

    2. WIRING Transceiver Unit 2.6.1 How to fabricate the 10P connector (CN-B102) Anticorrosive Insulating tape Core Shield sheath Expose cores then wind Vinyl Sheath shield around armor. Armor How to fabricate 10P connector Guide Pin A Guide Pin B Position No. Guide Pin A Guide Pin B (Large)
  • Page 34 2. WIRING How to position guide pins Use the guide pin insertion tool (Code No. 10-910-0179-0) to correctly insert guide pins to connectors. Connector Tool CN-B101 Guide pin Guide pin A (large) Guide pin B (small) (Guide pin insertion tool, notch in head) 1 3 - L CN-B210 CN-B209...
  • Page 35 2. WIRING 2.6.2 Connections inside the transceiver unit 1. Remove the transceiver unit cover. 2. Connect transducer cable (cables from the transducer) referring to cable no. la- beled on the chassis and connector no. labeled on each pc board. Connect the XH connector of the cable from the transducer to the TRX board.
  • Page 36: Transducer Cable Extension Kit

    2. WIRING Transducer Cable Extension Kit The transducer cable (10S2223, 10 pcs.) connects to the junction box of the kit and the junction box is connected to the transducer with a 5 m or 15 m cable (10S2240, 10 pcs.). The cable (10S2078, 8 m) that connects between the hull unit and transceiv- er unit is replaced with a 12.9 m cable (10S2078) or 22.9 m cable (10S2145), supplied with the kit.
  • Page 37: Control Box Of Hull Unit

    2. WIRING Control Box of Hull Unit Connect the 3 phase power cable and the transceiver unit cable (10S2078) as shown below. CN-C101 Connect the transceiver cable (10S2078) here. TB-C101 Connect the power cable to this terminal board. LED (red) For detection of phase reversal on 3 phase power cable Confirm that the LED lights in red after the wiring is completed.
  • Page 38: Input Voltage And Fuses

    2. WIRING Input Voltage and Fuses The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a 10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions and fuses shown below. Input voltage and toggle switch Default Input voltage...
  • Page 39: Adjustments And Checks

    ADJUSTMENTS AND CHECKS Hull Unit Check Do not transmit when the vessel is in dry dock. How to enable transmission The default transmission state is OFF. Enable transmission as shown in the procedure below. NEVER transmit when the vessel is in dry dock, to prevent damage to the transducer.
  • Page 40 3. ADJUSTMENTS AND CHECKS 5. Select [Test] then push the left-click button. Test Quit Board Test... : Execute Panel Test... : Execute Test Pattern... : Execute RX Test... : Execute Noise Test... : Execute : OFF 6. Select [TX] then push the left-click button. 7.
  • Page 41: How To Show The System Menu

    3. ADJUSTMENTS AND CHECKS TEST NORMAL L.SW UP MD DN DOWN 5. Release the [DOWN] switch during lowering to confirm that the transducer stops lowering. 6. Press the [DOWN] switch again to re-start lowering. Confirm that the transducer stops at the moment when the lower limit switch is pressed. 7.
  • Page 42: How To Adjust The Heading

    3. ADJUSTMENTS AND CHECKS 4. Click [Others] to show the system menu, to the right of the [Others] menu. Others Quit Edit User Program ... Interface Setting ES Setting ... EXT Data Setting 2D-MAP Disp Setting ... ES Setting ... Erase Marks ...
  • Page 43 3. ADJUSTMENTS AND CHECKS Heading correction at the motion sensor Heading correction at the motion sensor is done with [Heading Adjust 2] on the [Oth- ers] menu. • If the control box is mounted on the hull unit, set the same heading correction as entered for [Heading Adjust 1] (in [Others] menu).
  • Page 44: How To Configure The Own Ship Mark

    3. ADJUSTMENTS AND CHECKS How to Configure the Own Ship Mark Set your ship’s length and width and the position of the transducer, to accurately dis- play the own ship mark on the screen. 1. Refer to section 3.2 to show the system menu. 2.
  • Page 45: Others Menu

    3. ADJUSTMENTS AND CHECKS Others Menu This section provides information on the items of the system menu not mentioned in other sections. For how to display the system menu, see section 3.2. Others Quit Edit User Program ... Interface Setting ES Setting ...
  • Page 46 3. ADJUSTMENTS AND CHECKS 3.5.2 EXT Data Setting menu The [EXT Data Setting] menu sets up the external equipment connected to this sonar. Date&Time: Select the input format for date and time data. (NONE, CIF, NMEA) Heading: Select the input format for heading data. (NONE, AD10, CIF, NMEA) Speed&Course: Select the input format for ship’s speed and course data.
  • Page 47: Appendix 1 Jis Cable Guide

    EX: DPYCYS - 1.5 MPYC - 5 TTYCS-4 Designation type Designation type # of cores Core Area (mm The following reference table lists gives the measurements of JIS cables commonly used with Furuno products: Core Cable Core Cable Diameter Diameter...
  • Page 58 Y. Hatai...
  • Page 59 Y.NISHIYAMA 23/Apr/2013...
  • Page 60 Y.NISHIYAMA 23/Apr/2013...
  • Page 61 Y.NISHIYAMA 13/Sep/2011...
  • Page 62 Y.NISHIYAMA 13/Sep/2011...
  • Page 64 D-10...
  • Page 65 D-11...
  • Page 66 D-12 Y.NISHIYAMA 13/Sep/2011...
  • Page 67 D-13 Takahashi T Y. Hatai 11/Nov/2013 H.MAKI...
  • Page 68 クロ (FI-5002 OR CAN bus EQUIPMENT) NET-H シロ IV-2sq. NET-L アオ 注記 *1)造船所手配。 *2)オプション。 IV-8sq. *3)送受信機と上下装置との距離は標準で5m。延長キット使用で最大20m。 *4)現在未使用。 DRAWN TITLE FSV-35/35S T.YAMASAKI 19/Dec/2012 NOTE CHECKED 名称 カラースキャニングソナー H.MAKI *1: SHIPYARD SUPPLY. 19/Dec/2012 APPROVED *2: OPTION. 相互結線図 Y.NISHIYAMA 20/Dec/2012 *3: DISTANCE BETWEEN TRANSCEIVER UNIT AND HULL UNIT: 5 m STANDARD.