P2-2 Replace The Hydraulic Filters - Terex Genie GS-2646 AV Maintenance Manual

Table of Contents

Advertisement

June 2022
Kubota Models
D1105, WG972
• Radiator coolant (L.L.C.) - replace
• Battery - replace
• Radiator hoses and clamp bands - replace
• Fuel pipes and clamp bands - replace
• Intake air line - replace
WG972
• Fuel filter - replace
• LPG fuel hose and clamp bands - replace
• Coolant and vacuum lock hose of LPG
vaporizer - replace
GM Models
• Intake manifold - check for vacuum leaks
• Timing belt - replace
Part No. 1272215GT
Programmed Maintenance Procedures
P2-2
P2-2 Re place the Hy dra ulic Filt ers
Replace the Hydraulic Filters
Genie specifications require that this procedure be
performed every 2000 hours.
Replacement of the hydraulic tank return filter is
essential for good machine performance and
service life. A dirty or clogged filter may cause the
machine to perform poorly and continued use may
cause component damage. Extremely dirty
conditions may require that the filter be replaced
more often.
Tank breather filter (if equipped):
1
2
GS-30, GS-32, GS-46, GS-47, GS-69, GS-84, GS-
90
Replace the Hydraulic Return Filter
1
2
3
4
5
6
7
Scissor Lifts
Beware of hot oil. Contact with
hot oil may cause severe burns.
Remove and discard the hydraulic tank
breather cap.
Install a new cap onto the tank.
Clean the area around the oil filter. Remove
the filter with an oil filter wrench.
Apply a thin layer of fresh oil to the gasket of
the new oil filter.
Install the new filter and tighten it securely by
hand.
Use a permanent ink marker to write the date
and number of hours from the hour meter on
the oil filter.
Raise the platform to approximately 3 ft / 1 m.
Inspect the filter and related components to
be sure that there are no leaks.
Clean up and properly dispose of any oil that
may have spilled during the installation
procedure.