Service Manual
Checklist C Procedures
Chec k the Descent Del ay F uncti on
Check the Descent Delay
Function
1
Pull out the red Emergency Stop button to the
on position at the ground controls.
2
Lower the platform until the down limit switch
activates and the platform stops lowering.
Quickly release the controls and then
immediately attempt to lower the platform to
the stowed position.
Result: The platform will not lower for 4 to
6 seconds.
Result: The platform continues to lower.
Confirm that the descent delay option has
been selected to on. Refer to Repair
Procedure, How to Setup the Machine from
Ground Controls. Repeat this procedure.
3
Lower the platform to the stowed position.
Chec k the Down Limit Switc h H eight
Check the Down Limit Switch
Height
1
Raise the platform approximately 10 ft / 3 m.
2
Lower the platform until the down limit switch
activates and the platform stops lowering.
3
Push in the red Emergency Stop button to the
off position.
4
Measure the distance between the working
surface and the platform deck.
GS-2669
GS-3369
GS-4069
38
63 to 69 inches
1.6 to 1.75 m
66 to 72 inches
1.7 to 1.83 m
76 to 82 inches
1.9 to 2.1 m
GS-2669 BE • GS-3369 BE • GS-4069 BE
C-3
Replace the Hydraulic Tank
Breather Cap - Models with
Optional Hydraulic Oil
Genie specifications require that this procedure be
performed every 500 hours or six months,
whichever comes first.
The hydraulic tank is a vented-type tank. The
breather cap has an internal air filter that can
become clogged or, over time, can deteriorate. If
the breather cap is faulty or improperly installed,
impurities can enter the hydraulic system which
may cause component damage. Extremely dirty
conditions may require that the cap be inspected
more often.
1
Remove and discard the hydraulic tank
breather cap.
2
Install new cap onto the tank.
May 2015