9.PARAMETER DEFINITIONS—PPO Non Support Specification

9.1 Outline of PNU

You can use the PNU to make inverter settings from the network.
The data used with the network is denoted PNU(P) to differentiate it from the parameter (Pr.).
This chapter explains the Module type "E5NP".
CAUTION
Parameter definitions differ according to the Module type selected. When using "PPO type 1" to
"PPO type 5", refer to page 52.

9.2 Profibus PNU (Module type E5NP)

9.2.1 Real-time monitor (IND = 0000
The following items can be monitored from the master.
IND
PNU
0000
0
Output frequency
H
H
0000
1
Output current
H
H
0000
2
Output voltage
H
H
)
H
Item
60
Increments
0.01Hz
0.01A
0.1V