Name
0 to 15
PKW
PWE
16 to 31 Not used (0 is set)
Bit
PNU read value/write value
When command response AK = 7 (command execution error), PWE definition is as
follows.
0 Invalid PNU
1 Parameter value unchangeable (This error also occurs when Pr. 77 = 1)
2 Outside setting range
3 Invalid Sub-Index number
4 No array
11 No parameter change right
18 Other error *1
*1
Error Definition
• Outside AK number range
• External operation error
• Instruction code error
• With STR error
• Calibration error (Pr. 900 and later)
• Reset disabled error (per Pr. 75 reset input specification)
Profibus PROFILES—PPO Support Specification
Description
Error Definition
• Write data error
• Without option error
• With STF error
• With operation mode specification error