Advertisement

Profibus PROFILES—PPO Support Specification
Name
-
0 to 2
Control
enable
-
4 to 6
Fault
reset
-
8 to 9
PZD
enable
PZD STW
STF
signal
STR
signal
-
MRS
terminal
RAM/
2
E
PROM
*2 PZD enable and command count request can be executed.
Bit
Not used (1 is set)
0: Inverter output shutoff
3
1: Inverter output shutoff is cancelled
Not used (1 is set)
[At inverter error]
0: No action
7
1: Inverter reset (error reset)
[When inverter is normal]
No action
Not used (0 is set)
0: Command request of PZD is not processed.
10
1: Command request of PZD is processed.
• At power-on or inverter reset, set 1 once.
0: OFF
11
1: ON (Forward rotation command)
0: OFF
12
1: ON (Reverse rotation command)
13
Not used (0 is set)
0: MRS-OFF
Functions are changed depending on the Pr.183 setting. However, do not change the
14
"
factory-set value
6
0: Set frequency (HSW) is written to RAM (Power-on reset returns the changed set
frequency to the setting before it was written to RAM.).
15
1: Set frequency (HSW) is written to E
Description
1: MRS-ON (Output shutoff)
"
.
2
PROM.
40
(*1)