GRIP WARMER SYSTEM
CDI MAGNETO
1. Disconnect:
•
CDI magneto coupler
2. Connect:
•
Pocket tester
(to the CDI magneto coupler)
SEJ8410
3. Measure:
•
Grip warmer coil resistance
Out of specification → Replace the CDI mag-
neto.
Grip warmer coil resistance:
(Yellow/Black – Black)
SEJ8420
8-22
ELEC
1.51 ~ 1.85 Ω at 20°C (68°F)
–
+