Configuration Basics - Emerson Rosemount 2051 Reference Manual

Pressure transmitter with hart revision 5 and 7 selectable protocol
Hide thumbs Also See for Rosemount 2051:
Table of Contents

Advertisement

Reference Manual
00809-0100-4107
Example
Table 2-1: Rosemount 2051 Device Revisions and Files
Software
release
date
NAMUR
software
revision
August
2012
January
1998
(1)
NAMUR Software Revision is located on the hardware tag of the device
(2)
HART Software Revision can be read using a HART capable configuration tool.
(3)
Device Driver file names use Device and DD Revision, e.g. 10_01. HART Protocol is designed to
enable legacy device driver revisions to continue to communicate with new HART devices. To
access new functionality, the new Device Driver must be downloaded. It is recommended to
download new Device Driver files to ensure full functionality.
(4)
HART Revision 5 and 7 Selectable, Safety Certified, LOI, Scaled Variable, Configurable Alarms,
Expanded Engineering Units.
2.4

Configuration basics

CAUTION
Set all transmitter hardware adjustments during commissioning to avoid exposing the
transmitter electronics to the plant environment after installation.
The transmitter can be configured either before or after installation. Configuring the
transmitter on the bench using either a Field Communicator, AMS Device Manager, or LOI
ensures all transmitter components are in working order prior to installation. Verify that
the security switch is set in the unlock ( ) position in order to proceed with configuration.
See
Figure 4-2
2.4.1
Configuring on the bench
To configure on the bench, required equipment includes a power supply, and a Field
Communicator, AMS Device Manager, or an LOI (option M4). Wire equipment as shown in
Figure
must be present between the transmitter and the power supply, see
details. Connect the Field Communicator leads to the terminals labeled "COMM" on the
terminal block or 1–5 V configuration, wire as shown in
Communicator is connected to the terminals labeled VOUT/COMM.
Reference Manual
Identify device
HART
HART
software
universal
(1)
(2)
revision
revision
1.0.0
01
N/A
178
for switch location.
2-1. To ensure successful HART
Find Device Driver
Device
Reference
(3)
revision
manual
7
10
5
9
5
3
®
communication, a resistance of at least 250 Ωs
Figure
Configuration
September 2020
Review
Review
instructions
functionality
Changes to
software
(4)
Rosemount
2051
Reference
Manual
Rosemount
N/A
2051
Reference
Manual
Power supply
for
2-1. The Field
13

Hide quick links: