Fiber optic I/O board LED indications
On the fiber optic I/O boards, the input and
output LEDs on the transceivers light green
when 10G light is detected. The arrow
LEDs point to the input and output port they
represent (see figure 3).
In figure 3, SFP 1 and SFP 5 are examples of
the LEDs that indicate the input and output
port (different colors are used to indicate the
connection only).
Out 1 is red and the corresponding arrow LED is red.
In 1 is blue and the corresponding arrow LED is blue.
Out 5 is purple and the corresponding arrow LED is purple.
In 5 is green and the corresponding arrow LED is green.

Cooling Fan Assembly

Replaceable fan assembly (see
B
assembly has multiple fans (see
replace the fan assembly).

Ethernet Connection

NOTE: The following information is for the standard LAN port. If the device has
the IPCP Pro Matrix Q xi control card, which includes an AV LAN port, see
IPCP Pro Matrix Q xi Control Card
LAN Ethernet port — For IP control of the system, connect the matrix switcher to a
C
PC or an Ethernet LAN via this RJ-45 connector. Use a PC to control the networked
switcher with
and Control
anywhere in the world.
Link LED indicator — The green (link) LED indicates that the switcher is properly
connected to an Ethernet LAN. This LED should light steadily.
Act LED indicator — The yellow (activity) LED indicates transmission of
data packets on the RJ-45 connector. This LED should flicker as the switcher
communicates.
NOTE: The factory default settings are: IP address = 192.168.254.254,
Subnet mask = 255.255.255.0, Gateway = 0.0.0.0, and DHCP = Off
Cabling
It is vital that the Ethernet cables be the correct cable type and be properly terminated with
the correct pinout. Ethernet links use Category (CAT) 3, 5e, CAT 6, or CAT 7 unshielded
twisted pair (UTP) or shielded twisted pair (STP) cables, terminated with RJ-45 connectors.
Ethernet cables are limited to a length of 328 feet (100 meters).
NOTES:
Do not use standard telephone cables. Telephone cables do not support Ethernet.
Do not stretch or bend cables. Transmission errors can occur.
figure 2
Removing and Installing a Module
on page 15.
SIS Configuration
on page 22 or
Product Configuration Software
FOX3 Matrix Series Switchers • Installation
FOX3 MATRIX 8io
1
2
3
IN
IN
OUT
IN
OUT
OUT
6
7
5
IN
OUT
IN
OUT
IN
OUT
Figure 3.