Siemens SIDOOR AT40 System Manual page 78

Automatic door control units
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Controllers
5.5 Relay and field bus interfaces
Interface
The interface is implemented according to CiA 301, profile 417. The SIDOOR SERVICE TOOL must
be used to set the command input to CAN, so that the controller can be addressed via the CAN
bus. The factory settings of the major parameters are:
Parameter
Command output
CANopen node ID
Baud rate
Door number
CAN Cond. Monitoring*
* as of version 1.47
When the baud rate is set to "automatic", the CAN module automatically determines the baud
rate on the CAN bus. To do this, the CAN module must have received some valid CAN telegrams.
The LED H3 flashes at 10 Hz (quick flashing) while the baud rate is being automatically
determined.
LED signals
All LED signals are listed in the following table.
LED signal (H3)
(2.5 Hz)
(10 Hz)
76
Factory setting
CAN*
7
Automatic
1
OFF
CANopen state machine
"Stopped"
"Pre-operational"
"Operational"
Automatic determination of the baud rate
AT40 and ATD400V for elevators
System Manual, 06/2022, A5E42192709-AH