Siemens SIDOOR AT40 System Manual page 123

Automatic door control units
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Article number
Standard for safety
Ambient conditions
Ambient temperature during operation
min.
max.
Remark
Ambient temperature during storage/transportation
Storage, min.
Storage, max.
Transportation, min.
Transportation, max.
Altitude during operation relating to sea level
Installation altitude above sea level, max.
Relative humidity
No condensation, min.
No condensation, max.
Cables
Cable length
Input side
Output side
Connection method
Design of electrical connection at input
Design of electrical connection at output
Dimensions
Width
Height
Depth
AT40 and ATD400V for elevators
System Manual, 06/2022, A5E42192709-AH
6FB1112-0AT20-3PS0
EN 61010-1 / EN 61010-2-201
-20 °C
55 °C
No direct exposure to the sun
-20 °C
70 °C
-40 °C
70 °C
2 000 m
10 %
93 %
2 m
1.5 m
SCHUKO connector DIN 49.441, CEE7/VII
WAGO 721-103/026
270 mm
55 mm
80 mm