Connecting and commissioning
9.6 Final settings and checks
Risk of injury and material damage due to excessive closing or opening force of the door
Exceeding the maximum static closing and opening force may lead to personal injuries or
damage to the door drive and to mechanical components of the door.
The maximum static closing and opening forces at the closing edge without additional
protective equipment must not exceed 150 N (150 N in opening direction applies according to
EN81-20 only for glass leaf and folding leaf doors).
Risk of injury due to excessive closing force of the door
The door must be closed completely within the slow end distance in the closing direction. The
driving curve parameter "Cutter distance CLOSE" must be checked and set accordingly.
164
WARNING
WARNING
AT40 and ATD400V for elevators