SIDOOR functions
4.3 Extended functions
• Total electrical energy of the motor (as of FW version AT40 V01.48)
• Total mechanical energy of the motor (as of FW version AT40 V01.48)
Number of openings
The counter is incremented when an opening movement is started from the closed position. The
counter reading is stored retentively.
Number of obstructions
The counter is incremented when the door moves against an obstacle in closing direction. The
counter reading is stored retentively.
Number of learn runs
The counter is incremented when a learn run has been successfully completed. The counter
reading is stored retentively.
Number of power failures
The counter is incremented with a valid parameter set after a restart of the controller. The
counter reading is stored retentively.
Number of operating hours
The counter is incremented every hour, after 60 minutes of operation in each case, and stored
retentively. After a restart, the minute count restarts from zero. The counter for the operating
hours cannot be deleted.
Total electrical and mechanical energy of the motor (as of FW version AT40 V01.48)
• Total electrical energy consumed by the motor
• Total mechanical energy output by the motor
The electrical energy consumed by the motor and the mechanical energy generated are
continuously measured.
The energy values correspond to the current values at the time of the query. The energy
consumption can be determined for different situations by calculating the energy difference
between two points in time.
The measured electrical energy does not take into account the control unit's own energy
consumption.
56
AT40 and ATD400V for elevators
System Manual, 06/2022, A5E42192709-AH