Installing
6.1 General safety instructions for installation
Violation of the maximum permissible operating pressure
Danger of injury or poisoning
The maximum permissible operating pressure depends on the device version. The device can
be damaged if the maximum permissible operating pressure is exceeded. Hot, toxic and
corrosive process media can be released.
• Make sure that the device is suitable for the maximum permissible operating pressure of
Insufficient ventilation
Risk of fire
The device may overheat or start burning in the case of insufficient ventilation.
• Make sure that the room is sufficiently ventilated.
NOTICE
Improper installation
The device can be damaged or destroyed or its functionality impaired through an incorrect
installation.
• Make sure before installing the device that there is no visible damage.
• Ensure that the process connections are clean and that the seals and cable glands are
• Mount the device using a suitable tool.
NOTICE
Insufficient air circulation around the device
Device damage
The device may overheat in case of heat accumulation.
• Make sure that sufficient air circulates around the rack-mounted device.
• Do not cover the ventilation slit.
• If you install more than one rack-mounted device, maintain a clearance of one height unit
50
WARNING
your system. Refer to the information on the nameplate and/or in section "Technical
specifications (Page 117)".
WARNING
Refer to the information in section "Technical specifications (Page 117)".
suitable.
(4.5 cm) to the next device.
Rack-mounted device
Operating Instructions, A5E31874006-12