Advertisement

Article number
Name
A5E41261523
Pipe
A5E43472867
Pipe
A5E43472873
Pipe
A5E41042699
Pipe
A5E41262055
Pipe
A5E43472881
Pipe
A5E43472887
Pipe
A5E41042857
Pipe
A5E41263077
Pipe
A5E43472891
Pipe
A5E43472897
Pipe
A5E41042944
Pipe
A5E41264463
Pipe
A5E43472904
Pipe
A5E43472912
Pipe
Table A-17
Spare parts list ULTRAMAT 7 - other spare parts standard version
Article number
Name
A5E35255652
Heat sink
A5E35380097
IR radiation source
A5E35255666
Chopper
A5E35255667
Chopper
A5E35263882
Intermediate plate
A5E35263883
Optical decoupler
A5E35263884
FBG analyzer module
A5E35263885
FBG connector adapter
A5E35255654
Hose pressure sensor and
clamps
A5E34820355
O-rings
A5E41050801
O-rings
A5E35332928
O-rings
A5E41050939
O-rings
A5E35255695
O-rings
O-rings
Rack-mounted device
Operating Instructions, A5E31874006-12
Description
20 mm sample gas Hastelloy, cleaned for O
20 mm reference gas Hastelloy
20 mm reference gas Hastelloy, cleaned for O
60 mm sample gas
60 mm sample gas, cleaned for O
60 mm reference gas Hastelloy
60 mm reference gas Hastelloy, cleaned for O
90 mm sample gas Hastelloy
90 mm sample gas Hastelloy, cleaned for O
90 mm reference gas Hastelloy
90 mm reference gas, Hastelloy, cleaned for O
180 mm sample gas Hastelloy
180 mm sample gas Hastelloy, cleaned for O
180 mm reference gas, Hastelloy
180 mm reference gas, Hastelloy, cleaned for O
dation:
Description
Without setting system
Complete
complete sealed
For measured component CO
Printed circuit board analyzer module
Recommendation: Order pressure sensor hose, cable set and
cable tie set as well
Connector adapter printed circuit board analyzer module
Recommendation: Order pressure sensor hose, cable set and
cable tie set as well
Recommendation: Include Oetiker pliers in order
For FKM pipes, for sample gas path
For KALREZ-6375 pipes, for sample gas path
For analyzer chamber FKM, for sample gas path
For analyzer chamber Kalrez-6375, for sample gas path
FKM, for unsealed version, for all measured components ex‐
cept CO
2
O-rings for sample gas path not included.
FKM, for sealed version, for measured component CO
O-rings for sample gas path not included
A.5 Spare parts/accessories
2
2
2
2
2
2
2
Recommen‐
2
2
2
Appendix
Classifica‐
tion
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Classifica‐
tion
1
2
2
2
2
2
1
1
1
1
1
2
2
2
2
147