6
FORK, TRIPLE CLAMP
KliN1·
-o
Clamp the cartridge as shown in the figure.
Guideline
Use soft jaws.
Info
Clamp the cartridge only lightly.
The filling port must be located at the highest point.
During the filling procedure, the cartridge must be lower than the oil tank
of the vacuum pump.
The piston rod moves in and out during filling; do not immobilize it by
holding it with your hand.
Remove the screw of the filling port.
O
Mount special tool
on the cartridge.
Filling adapter (T14030) (,... p. 231)
Info
I
Hand-tighten only without using a tool.
Connect adapter @ to special tool
Connect adapter @ to the filling port of vacuum pump
I
Vacuum pump (T1240S) (,... p. 229)
Clamp the control lever as shown in the figure.
✓ Control lever
External tank
uum;
and
Oil reservoir
Activate
On/Off
switch (D.
✓ The suction process begins.
✓ Pressure gauge @ drops to the required value.
< 0 bar
@)
✓ Vacuum gauge
drops to the required value.
10 mbar
When the vacuum gauge reaches the required value, turn control lever
0
voir
to Equalize pressure.
Guideline
10 mbar
✓ The pressure gauge increases to the required value.
0 bar
When the pressure gauge reaches the required value, turn control lever
8
Damper
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the cartridge.
✓ The pressure gauge increases to the required value.
3 bar
O.
0.
CD
is set to
Closed; Damper
0
is set to
Vacuum.
35
e
is set to
Vac-
Oil reser­