Usage Notes
• The device may sustain damage from self-heating
• The product specifications that indicate the
• The detection frequency band for overload
16
even at current levels that are lower than the
maximum current value defined by the maximum
rated current.
The maximum rated current is a recommended
value that assumes sine-wave input under
standard conditions. Self-heating may increase
if the ambient temperature increases or the
measurement current waveform contains other
frequency components. Refer to the derating
characteristics in the product specifications
(p.  5 0).
maximum input range include a maximum peak
current value of ±7.5 A peak (non-continuous) in
addition to the maximum rated current. This value
constitutes an absolute upper limit that must
never be exceeded, even momentarily. Always
use the device within the specified range in order
to avoid damaging it.
warnings is DC and 45 to 66 Hz (sine wave).
When measuring currents that are outside the
detection frequency band, the overload warning
function may not operate. Under such conditions,
exercise caution so as not to exceed the
maximum rated current, regardless of whether the
OVERLOAD
CAUTION
LED is flashing.