Forth-Based Prom Diagnostics; Table 2-4 Selected Forth Diagnostic Tests - Sun Microsystems SPARCstation 4 110 Service Manual

Table of Contents

Advertisement

2.5

FORTH-Based PROM Diagnostics

For information about how to run the FORTH Diagnostics, see Appendix D.
TABLE 2-4
TABLE 2-4
Type of Test
Description
Tests the system video graphics
test screen
hardware and monitor.
Tests the floppy drive response to
test floppy
commands.
Tests the SCSI interface logic on
test scsi
the system board.
Performs a self-test diagnostic on
test cdrom
the CD-ROM drive.
Performs an internal and an
test net-aui
external loopback test on the AUI
(Thick) Ethernet interface.
Performs an internal and an
test net-tpe
external loopback test on the
twisted-pair Ethernet (TPE)
interface.
Performs an internal and an
test net
external loopback test on the auto-
selected system Ethernet interface.
2-8
SPARCstation 4 Model 110 Service Manual • July 1996
lists specific on-board diagnostic tests for your system.
Selected FORTH Diagnostic Tests
Preparation
The diag-switch? NVRAM
parameter must be set to true.
Insert a formatted diskette into
the drive.
The diag-switch? NVRAM
parameter must be set to true.
The CD-ROM must be set to
SCSI target 6 and have a CD
inserted in the drive or the test
will fail.
A cable must be connected to
the system AUI Ethernet port
and to an Ethernet tap or the
test will fail the external
loopback phase.
A cable must be connected to
the system TPE port and to a
TPE hub or the test will fail the
external loopback phase. If the
tpe-link-test? parameter
is false (disabled), the
external loopback test will
appear to pass even if a cable is
not connected.
A cable must be attached to the
system and to an Ethernet tap
or hub or the external loopback
test will fail.
When to Use
See description.
See description.
See description.
See description.
See description.
See description.
See description.