A.2
Input Power Requirements
TABLE A-2
TABLE A-2
Parameter
Nominal Frequencies
Nominal Voltage Range
Maximum Current AC RMS
AC Operating Range
Maximum VA Rating
Maximum Power Consumption
Maximum Heat Output
1. Maximum input current with accessory connected to accessory outlet is 6 A.
2. Maximum power consumption with monitor connected to accessory outlet is 203 Watts.
TABLE A-3
TABLE A-3
Parameter
Nominal Frequencies
Nominal Voltage Range
Maximum Current AC RMS
AC Operating Range
Maximum VA Rating
Maximum Power Consumption
Maximum Heat Output
1. Maximum input current with accessory outlet is 6A.
2. Maximum power consumption with monitor connected to accessory outlet is 249 Watts.
A-2
SPARCstation 4 Model 110 Service Manual • July 1996
lists the input power requirements for the SPARCstation 4 system.
Input Power Requirements and Power Dissipation—SPARCstation 4 System
1
2
lists the input power requirements for the SPARCserver 4 system.
Input Power Requirements and Power Dissipation—SPARCserver 4 System
1
2
Specification
50 Hz or 60 Hz nominal
100-120 Vac or 200-240 Vac
(100-240 Vac Auto)
0.75 A @ 100-120 Vac, 0.375 A @
200-240 Vac
87-264 Vrms, 47-63 Hz
75 VA
53 Watts
180.8 BTU/hr
Specification
50 Hz or 60 Hz nominal
100-120 Vac or 200-240 Vac
(100-240 Vac Auto)
1.0 A @ 100-120 Vac, 0.5 A @
200-240 Vac
87-264 Vrms, 47-63 Hz
100 VA
99 Watts
337.0 BTU/hr