Power Supply Leds - Lenovo ThinkSystem SR850P Maintenance Manual

Hide thumbs Also See for ThinkSystem SR850P:
Table of Contents

Advertisement

Table 43. Light path diagnostics: LED status and actions (continued)
LED
Identification button/
3
LED (blue)
System error LED
4
(yellow)

Power supply LEDs

This topic provides information about vatious power supply LED status and corresponding action
suggestions.
The following minimum configuration is required for the ac power LED on the power supply to be lit:
• Power supply
• Power cord
• Appropriate input power from the power source
The following minimum configuration is required for the server to start:
• 16 GB DIMM
• Two processors installed
• At least one 2.5-inch drive installed
• One power supply
• Power cord
The following table describes the problems that are indicated by various combinations of the power-supply
LEDs and the power-on LED on the front operator panel and suggested actions to correct the detected
problems.
Power supply LEDs
AC
DC
ThinkSystem SR850P Maintenance Manual
140
Description
This LED is used as a presence detection
LED. You can use Lenovo XClarity
Controller to light this LED remotely.
LED on: An error has occurred.
Error
Description
Action
Use this LED to locate the server among
other servers visually.
1. Look for other error LEDs lit in the
system (fans, DIMMs, power supplies,
etc).
2. Check the identification LED and
check log LED and follow the
instructions.
3. Check the Lenovo XClarity Controller
event log and the system-error log for
information about the error.
4. Save the log if necessary and clear the
log afterward.
Action
Note

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d2f7d2g7d2h

Table of Contents