Advertisement

Quick Links

ThinkSystem SR850 V3
Messages and Codes Reference
Machine Type: 7D96, 7D97, and 7D98

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo 7D96

  • Page 1 ThinkSystem SR850 V3 Messages and Codes Reference Machine Type: 7D96, 7D97, and 7D98...
  • Page 2 Before using this information and the product it supports, be sure to read and understand the safety information and the safety instructions, which are available at: https://pubs.lenovo.com/safety_documentation/ In addition, be sure that you are familiar with the terms and conditions of the Lenovo warranty for your server, which can be found at: http://datacentersupport.lenovo.com/warrantylookup First Edition (May 2023) ©...
  • Page 3: Table Of Contents

    Chapter 3. UEFI events ..139 Contacting Support ... . . 209 UEFI events organized by severity ..139 © Copyright Lenovo 2023...
  • Page 4 ThinkSystem SR850 V3 Messages and Codes Reference...
  • Page 5: Chapter 1. Messages

    Lenovo XClarity Provisioning Manager (although these events are not stored in the event log). Use this section to view the events that can be generated by Lenovo XClarity Controller, UEFI, or the Lenovo XClarity Provisioning Manager. For each event, a user action is available to help you understand what must be done to resolve the issue.
  • Page 6 – CA. Cooling - Fans, blowers, mux cards, policies, chillers/refrigeration, water management units, water pumps, water filtration, air flow sensors, thermal monitors. – DA. Display - Graphics adapters, op panel, monitor/console (including front/back panel, control panel, LCD panel etc). – IO. I/O connectivity - PCI/USB hub, bridge, bus, risers, configuration settings, interconnect, keyboard, mouse, KVM.
  • Page 7 – SR. LEPT Raid Setup. – SS. Service & Support - LEPT FFDC Collection. – SS. Systems Management - Service & Support. – TR. Time Reference - RTC, Master clock, drawer clocks, NTP. – UN. Unknown/any entity. – UP. LEPT Firmware Update. –...
  • Page 8 ThinkSystem SR850 V3 Messages and Codes Reference...
  • Page 9: Chapter 2. Xclarity Controller Events

    Chapter 2. XClarity Controller events When a hardware event is detected by the Lenovo XClarity Controller on the server, the Lenovo XClarity Controller writes that event in the system-event log on the server. Notes: Event identifier (ID) is a unique identifier used to search for XCC events. The event message may have one or more arguments, which could be replaceable text of FRU name or sensor name to identify the failed component.
  • Page 10: Xcc Events That Automatically Notify Support

    If you have configured this function and this field is set to Yes, Lenovo Support will be notified automatically if the event is generated. While you wait for Lenovo Support to call, you can perform the recommended actions for the event.
  • Page 11: Xcc Events Organized By Severity

    Table 1. Events that automatically notify Support (continued) Message String Event ID FQXSPIO0011N An Uncorrectable Error has occurred on [SensorElementName]. FQXSPIO0015M Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. FQXSPMA0007L Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. FQXSPMA0008N Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
  • Page 12 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPBR4009I Management Controller [arg1]: cloning configuration from neighbor Informational server [arg2] by group name [arg3]. FQXSPBR400AI Management Controller [arg1]: cloning configuration from neighbor Informational server [arg2] by group name [arg3] completed. FQXSPBR400BI Management Controller [arg1]: cloning configuration from neighbor Informational...
  • Page 13 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPDM4005I User [arg1] has generated a new encryption key pair and installed a Informational self-signed certificate for the TKLM client. FQXSPDM4006I User [arg1] has generated a new encryption key and certificate Informational signing request for the TKLM client.
  • Page 14 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPEM4016I The RAID controller detected one or more problems. Please contact Informational technical support for additional assistance.([arg1],[arg2],[arg3],[arg4], [arg5]) FQXSPEM4017I The RAID controller detected one or more possible configuration Informational changes within the subsystem.
  • Page 15 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPEM4033I Acoustic Mode [arg1] has been disengaged to allow adequate Informational cooling. FQXSPFC4000I The bare metal connection process has been started. Informational FQXSPFC4001I The bare metal update application reports a status of [arg1]. Informational FQXSPFC4002I System running in setup.
  • Page 16 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPNM4004I Ethernet locally administered MAC address modified from [arg1] to Informational [arg2] by user [arg3]. FQXSPNM4005I Ethernet interface [arg1] by user [arg2]. Informational FQXSPNM4006I Hostname set to [arg1] by user [arg2]. Informational Informational FQXSPNM4007I...
  • Page 17 User [arg1] has set the SMTP Server reverse-path to [arg2]. Informational FQXSPNM4052I DHCP specified hostname is set to [arg1] by user [arg2]. Informational FQXSPNM4053I DNS discovery of Lenovo XClarity Administrator has been [arg1] by Informational user [arg2]. FQXSPNM4054I The hostname from DHCP is [arg1] by user [arg2]. Informational FQXSPNM4055I The hostname from DHCP is invalid.
  • Page 18 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPNM4060I IP address of default gateway of network interface [arg1] is modified Informational from [arg2] to [arg3] by user [arg4]. FQXSPOS4000I OS Watchdog response [arg1] by [arg2] . Informational FQXSPOS4001I Watchdog [arg1] Screen Capture Occurred .
  • Page 19 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPPP4020I The measured power value has returned below the power cap value. Informational FQXSPPP4021I The new minimum power cap value has returned below the power cap Informational value. FQXSPPP4022I The server was restarted for an unknown reason.
  • Page 20 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPPP4049I Management Controller [arg1] reset was initiated by Front Panel. Informational Informational FQXSPPP4050I Management Controller [arg1] reset was initiated to activate PFR Firmware. FQXSPPR0000I [ManagedElementName] detected as present. Informational FQXSPPR2000I [ManagedElementName] detected as present.
  • Page 21 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSD0000I The [StorageVolumeElementName] has been added. Informational FQXSPSD0003I Hot Spare enabled for [ComputerSystemElementName]. Informational FQXSPSD0005I Hot Spare enabled for drive [arg1] in the enclosure/chassis (MTM-SN: Informational [arg2]). FQXSPSD0007I Rebuild in progress for Array in system Informational [ComputerSystemElementName].
  • Page 22 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSE4007I Security: Userid: [arg1] using [arg2] had [arg3] login failures from an Informational SSH client at IP address [arg4]. FQXSPSE4008I SNMPv1 [arg1] set by user [arg2]: Name=[arg3], AccessType=[arg4], Informational Address=[arg5], .
  • Page 23 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSE4028I Security: Userid: [arg1] had [arg2] login failures from IPMI client at IP Informational address [arg3]. FQXSPSE4029I Security: Userid: [arg1] had [arg2] login failures from SNMP client at IP Informational address [arg3].
  • Page 24 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSE4054I IPMI SEL wrapping mode is [arg1] by user [arg2] at IP address [arg3]. Informational FQXSPSE4055I SED encryption is enabled by user [arg1] at IP address [arg2]. Informational FQXSPSE4056I SED AK is [arg1] by user [arg2] at IP address [arg3].
  • Page 25 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPSS4011I Fan speed boost setting is changed from [arg1] to [arg2]. Informational Informational FQXSPTR4000I Management Controller [arg1] clock has been set from NTP server [arg2]. FQXSPTR4001I Date and Time set by user [arg1]: Date=[arg2], Time-[arg3], DST Auto- Informational adjust=[arg4], Timezone=[arg5].
  • Page 26 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPDM4002I Device [arg1] VPD is not valid. Warning Warning FQXSPIO0014J Bus [SensorElementName] is operating in a degraded state. FQXSPIO2000J The connector [PhysicalConnectorElementName] has been Warning disconnected. FQXSPIO4001I GPU Board Status was changed by [arg1] of [arg1]. Warning FQXSPMA0010J [PhysicalMemoryElementName] on Subsystem...
  • Page 27 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPBR4008I Management Controller [arg1]: Configuration restoration from a file by Error user [arg2] failed to start. FQXSPCA0002M Numeric sensor [NumericSensorElementName] going low (lower Error critical) has asserted. FQXSPCA0009M Numeric sensor [NumericSensorElementName] going high (upper Error critical) has asserted.
  • Page 28 Table 2. Events organized by severity (continued) Message String Severity Event ID FQXSPOS4002I Watchdog [arg1] Failed to Capture Screen. Error Error FQXSPOS4003I Platform Watchdog Timer expired for [arg1]. FQXSPOS4010I OS Crash Video Capture Failed. Error FQXSPPU0001N An Over-Temperature Condition has been detected on Error [ProcessorElementName].
  • Page 29: List Of Xclarity Controller Events

    3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPBR4002I: Management Controller [arg1] Reset was caused by restoring default values. This message is for the use case where a Management Controller has been reset due to a user restoring the configuration to default values.
  • Page 30 4. Disable the watchdog timer. 5. Check the integrity of the installed operating system. 6. If problem persists, collect Service Data log. 7. Contact Lenovo Support. • FQXSPBR4004I: Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2], OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4], LoaderTimeout=[arg5]. A user configures Server Timeouts...
  • Page 31 1. Retry the operation. 2. AC cycle the system. 3. If Problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPBR4008I: Management Controller [arg1]: Configuration restoration from a file by user [arg2] failed to start. This message is for the use case where a user restores a Management Controller configuration from a file and the restoration fails to start.
  • Page 32 2. Retry the operation. 3. AC cycle the system. 4. If problem persists, collect Service Data log. 5. Contact Lenovo Support. • FQXSPBR4009I: Management Controller [arg1]: cloning configuration from neighbor server [arg2] by group name [arg3]. This message is for the use case where a user synchronizes a Management Controller configuration by Federation.
  • Page 33 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0258 User Action: Information only; no action is required. • FQXSPBR400DI: Neighbor group clone configuration was initiated by user [arg1]. This message is for the user initiated a Federation clone configuration.
  • Page 34 Complete the following steps: 1. Ensure fans are installed correctly. 2. If fan is installed with issue , please reinstall fan. 3. If the problem still exist, then please contact Lenovo support. • FQXSPCA0007J: Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
  • Page 35 1. Ensure the room temporature is within server environmental specification to adjust the temporature. 2. If the problem issue still exist, check XCC Web GUI to check the temporature value is still higher than system spec. 3. Please contact Lenovo support. • FQXSPCA0011N: Numeric sensor [NumericSensorElementName] going high (upper non- recoverable) has asserted.
  • Page 36 • FQXSPCA0019N: Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. This message is for the use case when an implementation has detected a Sensor transitioned to non- recoverable from less severe. Severity: Error Serviceable: Yes Automatically notify Support: No Alert Category: Critical - Temperature SNMP Trap ID: 0 CIM Prefix: PLAT CIM ID: 0524...
  • Page 37 This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Temperature SNMP Trap ID: 0 CIM Prefix: PLAT CIM ID: 0495 User Action: Information only;...
  • Page 38 Information only; no action is required • FQXSPCN4000I: Serial Redirection set by user [arg1]: Mode=[arg2], BaudRate=[arg3], StopBits= [arg4], Parity=[arg5], SessionTerminateSequence=[arg6]. A user configured the Serial Port mode Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0078 User Action:...
  • Page 39 • FQXSPCR0001N: Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. This message is for the use case when an implementation has detected a Sensor transitioned to non- recoverable from less severe. Severity: Error Serviceable: Yes Automatically notify Support: No Alert Category: Critical - Other SNMP Trap ID: 50 CIM Prefix: PLAT CIM ID: 0524...
  • Page 40 SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0142 User Action: Collect Service Data log and contact Lenovo Support. • FQXSPDM4003I: TKLM servers set by user [arg1]: TKLMServer1=[arg2] Port=[arg3], TKLMServer2= [arg4] Port=[arg5], TKLMServer3=[arg6] Port=[arg7], TKLMServer4=[arg8] Port=[arg9]. A user configured the TKLM servers...
  • Page 41 SNMP Trap ID: CIM Prefix: IMM CIM ID: 0148 User Action: Information only; no action is required. • FQXSPDM4006I: User [arg1] has generated a new encryption key and certificate signing request for the TKLM client. User generated a new encryption key and certificate signing request for the TKLM client Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 42 User Action: Information only; no action is required. • FQXSPEA0002M: Sensor [SensorElementName] has transitioned to critical from a less severe state. This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe. Severity: Error Serviceable: Yes Automatically notify Support: No...
  • Page 43 User Action: To avoid losing older log entries, save the log as a text file and clear the log. • FQXSPEM4003I: LED [arg1] state changed to [arg2] by [arg3]. A user has modified the state of an LED Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other...
  • Page 44 Information only; no action is required. • FQXSPEM4007I: Alert Recipient Number [arg1] updated: Name=[arg2], DeliveryMethod=[arg3], Address=[arg4], IncludeLog=[arg5], Enabled=[arg6], EnabledAlerts=[arg7], AllowedFilters=[arg8] by user [arg9] from [arg10] at IP address [arg11]. A user adds or updates an Alert Recipient Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID:...
  • Page 45 • FQXSPEM4011I: XCC failed to log previous event [arg1]. XCC failed to log a previous event. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0196 User Action: Information only;...
  • Page 46 • FQXSPEM4015I: The RAID controller detected unrecoverable error. The controller needs replacement.([arg1],[arg2],[arg3],[arg4],[arg5]) The RAID controller detected unrecoverable error Severity: Info Serviceable: No Automatically notify Support: Yes Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0204 User Action: Information only;...
  • Page 47 Information only; no action is required. • FQXSPEM4019I: Connectivity issue detected with the enclosure/chassis. Please check your cable configurations to repair the problem.([arg1],[arg2],[arg3],[arg4],[arg5]) Connectivity issue detected with the enclosure/chassis Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0208 User Action:...
  • Page 48 CIM Prefix: IMM CIM ID: 0211 User Action: Information only; no action is required. • FQXSPEM4024I: The RAID controller detected one or more possible configuration problem within the subsystem. Please check the event logs and if events are targeted to the same disk then replace the drive.
  • Page 49 Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0215 User Action: Information only; no action is required. • FQXSPEM4028I: The port [arg1] of PCIe device [arg2] at [arg3] has link [arg4]. PCI device link Severity: Info Serviceable: No...
  • Page 50 Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0273 User Action: Information only; no action is required. • FQXSPEM4032I: Acoustic Mode [arg1] has been engaged. Fan speed limits are in place. This message is for the use case where Acoustic Mode is engaged.
  • Page 51 SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0144 User Action: Information only; no action is required. • FQXSPFC4002I: System running in setup. System running in setup Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0193 User Action:...
  • Page 52 3. Undo recent system changes (settings or devices added). Verify that the system boots. Then, re- install options one at a time to locate the problem. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error. Update UEFI firmware if applicable.
  • Page 53 If the NMI button has not been pressed, complete the following steps: 1. Reboot the system. 2. If error still exist, then collect serivce log and contact Lenovo support. • FQXSPIO0004L: A bus timeout has occurred on bus [SensorElementName]. This message is for the use case when an implementation has detected a Bus Timeout.
  • Page 54 Serviceable: Yes Automatically notify Support: No Alert Category: Critical - Other SNMP Trap ID: 50 CIM Prefix: PLAT CIM ID: 0228 User Action: Check the event log in system event log to resolve any issues related the NMI • FQXSPIO0007N: A PCI PERR has occurred on system [ComputerSystemElementName]. This message is for the use case when an implementation has detected a PCI PERR.
  • Page 55 2. Check the event log of XClarity Controller for additional information about failing components. 3. If there are no entries related to the error in the event log, contact Lenovo support • FQXSPIO0013N: A Fatal Bus Error has occurred on bus [SensorElementName].
  • Page 56 2. Check the event log of XClarity Controller for additional information about failing components. Check http://support.lenovo.com/ for TECH tips or firmware updates that might correct the error. 3. If there are no entries related to the error in the event log, contact Lenovo support • FQXSPIO2000J: The connector [PhysicalConnectorElementName] has been disconnected.
  • Page 57 CIM Prefix: PLAT CIM ID: 0225 User Action: Information only; no action is required • FQXSPIO2006I: System [ComputerSystemElementName] has recovered from an NMI. This message is for the use case when an implementation has detected a Software NMI has been Recovered from.
  • Page 58 User Action: Information only; no action is required. • FQXSPIO2014I: Bus [SensorElementName] is no longer operating in a degraded state. This message is for the use case when an implementation has detected a Bus is No Longer Degraded. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Warning - Other...
  • Page 59 3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version. 4. If the problem persists, collect Service Data logs. 5. Contact Lenovo Support. • FQXSPMA0007L: Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
  • Page 60 3. If problem recurs on the same DIMM connector, replace the other DIMMs on the same memory channel. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error. 5. If problem recurs on the same DIMM connector, inspect connector for damage. If damage found or problem persists, collect Service Data log.
  • Page 61 3. If problem recurs on the same DIMM connector, replace the other DIMMs on the same memory channel. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error. 5. If problem recurs on the same DIMM connector, inspect connector for damage. If damage found or problem persists, collect Service Data log.
  • Page 62 3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version. 4. If the problem persists, collect Service Data logs. 5. Contact Lenovo Support. • FQXSPMA2007I: Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered.
  • Page 63 Information only; no action is required • FQXSPMA2024I: Sensor [SensorElementName] has deasserted. This message is for the use case when an implementation has detected a Sensor has deasserted. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Warning - Memory SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0509 User Action:...
  • Page 64 This message is for the use case where a user modifies the Ethernet Port MTU setting. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0005 User Action: Information only;...
  • Page 65 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - IMM Network event SNMP Trap ID: 37 CIM Prefix: IMM CIM ID: 0009 User Action: Information only; no action is required. • FQXSPNM4008I: IP subnet mask of network interface modified from [arg1] to [arg2] by user [arg3]. This message is for the use case where a user modifies the IP subnet mask of a Management Controller.
  • Page 66 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPNM4011I: ENET[[arg1]] DHCP-HSTN=[arg2], DN=[arg3], IP@=[arg4], SN=[arg5], GW@= [arg6], DNS1@=[arg7] . This message is for the use case where a Management Controller IP address and configuration has been assigned by the DHCP server.
  • Page 67 User Action: Information only; no action is required. • FQXSPNM4015I: DHCP setting changed to [arg1] by user [arg2]. This message is for the use case where a user changes the DHCP setting. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0026...
  • Page 68 • FQXSPNM4019I: DDNS registration successful. The domain name is [arg1]. DDNS registation and values Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - IMM Network event SNMP Trap ID: CIM Prefix: IMM CIM ID: 0046 User Action: Information only;...
  • Page 69 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0050 User Action: Information only; no action is required. • FQXSPNM4024I: IPv6 stateless auto-configuration enabled by user [arg1]. IPv6 statless auto-assignment method is enabled by user Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 70 Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0054 User Action: Information only; no action is required. • FQXSPNM4028I: ENET[[arg1]] IPv6-LinkLocal:HstName=[arg2], IP@=[arg3] ,Pref=[arg4] . IPv6 Link Local address is active Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - IMM Network event SNMP Trap ID: CIM Prefix: IMM CIM ID: 0055...
  • Page 71 2. Make sure that there is a DHCPv6 server on the network that can assign an IP address to the XCC/ BMC. 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPNM4033I: Telnet port number changed from [arg1] to [arg2] by user [arg3]. A user has modified the telnet port number...
  • Page 72 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0063 User Action: Information only; no action is required. • FQXSPNM4036I: Web-HTTPS port number changed from [arg1] to [arg2] by user [arg3]. A user has modified the Web HTTPS port number Severity: Info Serviceable: No...
  • Page 73 Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0067 User Action: Information only; no action is required. • FQXSPNM4040I: SNMP Traps port number changed from [arg1] to [arg2] by user [arg3]. A user has modified the SNMP Traps port number Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 74 User Action: Information only; no action is required. • FQXSPNM4044I: Telnet [arg1] by user [arg2]. A user enables or disables Telnet services Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0087 User Action: Information only;...
  • Page 75 User Action: Information only; no action is required. • FQXSPNM4048I: PXE boot requested by user [arg1]. PXE boot requested Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0129 User Action: Information only;...
  • Page 76 SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0216 User Action: Information only; no action is required. • FQXSPNM4053I: DNS discovery of Lenovo XClarity Administrator has been [arg1] by user [arg2]. DNS discovery of Lenovo XClarity Administrator Severity: Info Serviceable: No...
  • Page 77 Report NTP server invalid Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - IMM Network event SNMP Trap ID: 37 CIM Prefix: IMM CIM ID: 0249 User Action: Information only; no action is required. • FQXSPNM4057I: Security: IP address: [arg1] had [arg2] login failures, it will be blocked to access for [arg3] minutes.
  • Page 78 • FQXSPNM4060I: IP address of default gateway of network interface [arg1] is modified from [arg2] to [arg3] by user [arg4]. This message is for the use case where a user modifies the default gateway IP address of a Management Controller. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 79 3. Reinstall the RNDIS or cdc_ether device driver for the operating system. 4. Disable the watchdog. 5. If problem persists, collect Service Data log. 6. Contact Lenovo Support.Check the integrity of the installed operating system. • FQXSPOS4004I: Operating System status has changed to [arg1]. Operating System status change...
  • Page 80 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0231 User Action: Information only; no action is required. • FQXSPOS4006I: Host Power-On password cleared by user [arg1] from [arg2] at IP address [arg3]. This message is for the use case where Host Power-On password cleared.
  • Page 81 2. Check if the crash video recording is enabled 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPOS4011I: OS failure screen capture with hardware error is [arg1] by user [arg2] from [arg3] at IP address [arg4].
  • Page 82 A user configured the Server Power Off Delay Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0081 User Action: Information only; no action is required. • FQXSPPP4002I: Server [arg1] scheduled for [arg2] at [arg3] by user [arg4]. A user configured a Server Power action at a specific time Severity: Info Serviceable: No...
  • Page 83 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0113 User Action: Information only; no action is required. • FQXSPPP4006I: The minimum power cap value changed from [arg1] watts to [arg2] watts. Minimum Power Cap value changed Severity: Info Serviceable: No...
  • Page 84 CIM Prefix: IMM CIM ID: 0117 User Action: Information only; no action is required. • FQXSPPP4010I: The new minimum power cap value exceeded the power cap value. Minimum Power Cap exceeds Power Cap Severity: Warning Serviceable: No Automatically notify Support: No Alert Category: Warning - Power SNMP Trap ID: 164 CIM Prefix: IMM CIM ID: 0118...
  • Page 85 Information only; no action is required. • FQXSPPP4014I: Static Power Savings mode has been turned off by user [arg1]. Static Power Savings mode turned off by user Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0122 User Action:...
  • Page 86 External throttling occurred Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0126 User Action: Information only; no action is required. • FQXSPPP4019I: Power cap throttling occurred. Power cap throttling occurrred Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 87 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0166 User Action: Information only; no action is required. • FQXSPPP4023I: The server is restarted by chassis control command. Server is restarted by chassis control command Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 88 CIM Prefix: IMM CIM ID: 0170 User Action: Information only; no action is required. • FQXSPPP4027I: The server was restarted for OEM reason. Server was restarted for OEM reason Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0171 User Action:...
  • Page 89 CIM Prefix: IMM CIM ID: 0174 User Action: Information only; no action is required. • FQXSPPP4031I: The server was power-cycled via Platform Event Filter. Server was power-cycled via Platform Event Filter Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0175 User Action:...
  • Page 90 Information only; no action is required. • FQXSPPP4035I: The server was powered off by chassis control command. Server was powered off by chassis control command Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0179 User Action: Information only;...
  • Page 91 • FQXSPPP4039I: The server stayed powered off because the power restore policy is set to restore previous power state.. Server stayed powered off because the power restore policy is set to restore previous power state. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0183...
  • Page 92 Management Controller reset was initiated by PRESET Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0187 User Action: Information only; no action is required. • FQXSPPP4044I: Management Controller [arg1] reset was initiated by CMM. Management Controller reset was initiated by CMM Severity: Info Serviceable: No...
  • Page 93 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0227 User Action: Information only; no action is required. • FQXSPPP4049I: Management Controller [arg1] reset was initiated by Front Panel. Management Controller reset was initiated by Front Panel Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 94 Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0390 User Action: The device is detected • FQXSPPR2001I: [ManagedElementName] detected as absent. This message is for the use case when an implementation has detected a Managed Element is Absent. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 95 User Action: Complete the following steps: 1. If the system board or firmware was just updated, check the Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error. 2. If problem persists, collect Service Data log.
  • Page 96 CIM Prefix: PLAT CIM ID: 0062 User Action: Complete the following steps: 1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error. 2. If problem persists, collect Service Data log. 3. Contact Lenovo Support.
  • Page 97 This message is for the use case when an implementation has detected a Processor is no longer running in the Degraded state. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Warning - CPU SNMP Trap ID: 42 CIM Prefix: PLAT CIM ID: 0039 User Action: Information only;...
  • Page 98 • FQXSPPW0005I: [PowerSupplyElementName] is operating in an Input State that is out of range. This message is for the use case when an implementation has detected a Power Supply that has input out of range. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0098...
  • Page 99 • FQXSPPW0009I: [PowerSupplyElementName] has been Power Cycled. This message is for the use case when an implementation has detected a Power Unit that has been power cycled. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0108 User Action:...
  • Page 100 If the problem remains, replace the system board (trained technician only). 3. Contact local service provider. To locate a reseller authorized by Lenovo to provide warranty service, go to http://www.ibm.com/partnerworld and click Business Partner Locator.
  • Page 101 Automatically notify Support: No Alert Category: Warning - Redundant Power Supply SNMP Trap ID: 10 CIM Prefix: PLAT CIM ID: 0804 User Action: Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the system.
  • Page 102 User Action: Information only; no action is required • FQXSPPW2002I: [PowerSupplyElementName] has returned to OK status. This message is for the use case when an implementation has detected a Power Supply return to normal operational status. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Power SNMP Trap ID: 4...
  • Page 103 User Action: Information only; no action is required • FQXSPPW2008I: [PowerSupplyElementName] has been turned on. This message is for the use case when an implementation has detected a Power Unit that has been Enabled. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Power On SNMP Trap ID: 24 CIM Prefix: PLAT CIM ID: 0107...
  • Page 104 Automatically notify Support: No Alert Category: Warning - Power SNMP Trap ID: 164 CIM Prefix: PLAT CIM ID: 0521 User Action: Information only; no action is required • FQXSPPW2061I: Sensor [SensorElementName] has transitioned to a less severe state from critical. This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.
  • Page 105 Serviceable: No Automatically notify Support: No Alert Category: Warning - Redundant Power Supply SNMP Trap ID: 10 CIM Prefix: PLAT CIM ID: 0807 User Action: Information only; no action is required. • FQXSPPW2110I: Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted. This message is for the use case when a Redundancy Set has transitioned from Non-redundant: Insufficient Resources.
  • Page 106 CIM Prefix: PLAT CIM ID: 0164 User Action: Complete the following steps: 1. Check the Support Portal(http://support.lenovo.com/)for service bulletins and TECH tips and firmware update related to your drive. 2. Check for any other RAID-related error. 3. Replace the drive.
  • Page 107 User Action: Replace hard disk drive 0 at the next maintenance period. • FQXSPSD0003I: Hot Spare enabled for [ComputerSystemElementName]. This message is for the use case when an implementation has detected a Hot Spare has been Enabled. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID:...
  • Page 108 1. Replace any hard disk drive that is indicated by a lit status LED. 2. Re-create the array. 3. Restore the data from a backup. • FQXSPSD0007I: Rebuild in progress for Array in system [ComputerSystemElementName]. This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.
  • Page 109 User Action: Complete the following steps: 1. Replace any hard disk drive that is indicated by a lit status LED. 2. Re-create the array. 3. Restore the data from a backup. • FQXSPSD2000I: The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].
  • Page 110 This message is for the use case when an implementation has detected a Hot Spare has been Disabled. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0171 User Action: Information only;...
  • Page 111 This message is for the use case when an implementation has detected a Drive was Enabled. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Hard Disk drive SNMP Trap ID: 5 CIM Prefix: PLAT CIM ID: 0167 User Action: Information only;...
  • Page 112 • FQXSPSD2014I: Array restored on drive [arg1] in the enclosure/chassis (MTM-S/N: [arg2]). This message is for the use case when an implementation has detected that a Failed Array has been Restored. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Critical - Hard Disk drive SNMP Trap ID: 5 CIM Prefix: PLAT CIM ID: 0177 User Action:...
  • Page 113 1. Make sure that the certificate that you are importing is correct and properly generated. 2. If problem persists, collect Service Data log. 3. Contact Lenovo Support. • FQXSPSE4001I: Remote Login Successful. Login ID: [arg1] using [arg2] from [arg3] at IP address [arg4].
  • Page 114 Serviceable: No Automatically notify Support: No Alert Category: System - Remote Login SNMP Trap ID: 30 CIM Prefix: IMM CIM ID: 0017 User Action: Complete the following steps until the problem is solved: 1. Make sure that the correct login ID and password are being used. 2.
  • Page 115 1. Make sure that the certificate that you are importing is correct and properly generated / certificate CSR is correct 2. If problem persists, collect Service Data log. 3. Contact Lenovo Support. • FQXSPSE4007I: Security: Userid: [arg1] using [arg2] had [arg3] login failures from an SSH client at IP address [arg4].
  • Page 116 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0077 User Action: Information only; no action is required. • FQXSPSE4011I: Secure Web services (HTTPS) [arg1] by user [arg2]. A user enables or disables Secure web services Severity: Info Serviceable: No...
  • Page 117 Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0094 User Action: Information only; no action is required. • FQXSPSE4015I: Global Login General Settings set by user [arg1]: AuthenticationMethod=[arg2], LockoutPeriod=[arg3], SessionTimeout=[arg4]. A user changes the Global Login General Settings Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 118 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0101 User Action: Information only; no action is required. • FQXSPSE4019I: User [arg1] password modified. A user account was changed Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID:...
  • Page 119 SNMP Trap ID: CIM Prefix: IMM CIM ID: 0105 User Action: Information only; no action is required. • FQXSPSE4023I: SSH Client key added for user [arg1] by user [arg2] from [arg3] at IP address [arg4]. User locally defined an SSH Client key Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 120 Alert Category: System - Remote Login SNMP Trap ID: 30 CIM Prefix: IMM CIM ID: 0140 User Action: Information only; no action is required. • FQXSPSE4027I: Remote access attempt failed. Invalid userid or password received. Userid is [arg1] from a CIM client at IP address [arg2]. This message is for the use case where a remote user has failed to establish a remote control session from CIM.
  • Page 121 Serviceable: No Automatically notify Support: No Alert Category: System - Remote Login SNMP Trap ID: 30 CIM Prefix: IMM CIM ID: 0155 User Action: Information only; no action is required. • FQXSPSE4031I: Remote Login Successful. Login ID: [arg1] from [arg2] serial interface. This message is for the use case where a user successfully logs in to a Management Controller.
  • Page 122 SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0164 User Action: Information only; no action is required. • FQXSPSE4035I: A certificate has been revoked . A certificate has been revoked Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0165 User Action:...
  • Page 123 User Action: Information only; no action is required. • FQXSPSE4039I: Temporary user account [arg1] is created by inband tool. Temporary user account create Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0228 User Action: Information only;...
  • Page 124 Information only; no action is required. • FQXSPSE4043I: Retrieving the third-party password [arg1] by user [arg2] from [arg3] at IP address [arg4]. This message is for the use case where a user successfully switch the retrieving the third-party password. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other...
  • Page 125 Information only; no action is required. • FQXSPSE4047I: Role [arg1] is [arg2] and assigned with custom privileges [arg3][arg4][arg5][arg6] [arg7][arg8][arg9][arg10][arg11] by user [arg12] . Role create modify and assign Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0246 User Action:...
  • Page 126 • FQXSPSE4051I: Management Controller [arg1] joined the neighbor group [arg2] by user [arg3] at IP address [arg4]. This message is for the use case where MC joins a group. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0261 User Action:...
  • Page 127 • FQXSPSE4055I: SED encryption is enabled by user [arg1] at IP address [arg2]. SED encryption is enabled. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0265 User Action: Information only;...
  • Page 128 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0269 User Action: Information only; no action is required. • FQXSPSE4060I: User [arg1] role set to [arg2] by user [arg3] from [arg4] at IP address [arg5]. A user account role assigned by user Severity: Info Serviceable: No...
  • Page 129 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0279 User Action: Information only; no action is required. • FQXSPSE4064I: SNMPv3 engine ID is changed from [arg1] to [arg2] by user [arg3] from [arg4] at IP address [arg5].
  • Page 130 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0285 User Action: Information only; no action is required. • FQXSPSR0001N: Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
  • Page 131 • FQXSPSS4001I: Server General Settings set by user [arg1]: Name=[arg2], Contact=[arg3], Location=[arg4], Room=[arg5], RackID=[arg6], Rack U-position=[arg7], Address=[arg8]. A user configured the Location setting Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0080 User Action: Information only;...
  • Page 132 Manual Call Home by user. Severity: Info Serviceable: No Automatically notify Support: Yes Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0135 User Action: Information only; no action is required. • FQXSPSS4006I: Call Home to [arg1] failed to complete: [arg2]. Call Home failed to complete.
  • Page 133 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: 22 CIM Prefix: IMM CIM ID: 0226 User Action: Information only; no action is required. • FQXSPSS4010I: Test Audit Log generated by user [arg1]. This message is for the use case where OS Crash Video Capture Failed. Severity: Info Serviceable: No Automatically notify Support: No...
  • Page 134 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: IMM CIM ID: 0079 User Action: Information only; no action is required. • FQXSPTR4002I: Synchronize time setting by user [arg1]: Mode=Sync with NTP Server, NTPServerHost1=[arg2]:[arg3],NTPServerHost2=[arg4]:[arg5],NTPServerHost3=[arg6]:[arg7], NTPServerHost4=[arg8]:[arg9],NTPUpdateFrequency=[arg10].
  • Page 135 Severity: Info Serviceable: No Automatically notify Support: No Alert Category: Warning - Other SNMP Trap ID: 60 CIM Prefix: PLAT CIM ID: 0518 User Action: Information only; no action is required • FQXSPUN0018J: Sensor [SensorElementName] has transitioned from normal to non-critical state. This message is for the use case when an implementation has detected a Sensor transitioned to non- critical from normal.
  • Page 136 Complete the following steps: 1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this error. 2. Reboot the system. 3. If the error continues, replace the system-board assembly (see hardware maintenance manual).
  • Page 137 CIM Prefix: PLAT CIM ID: 0509 User Action: Information only; no action is required • FQXSPUN2018I: Sensor [SensorElementName] has deasserted the transition from normal to non- critical state. This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.
  • Page 138 Alert Category: Critical - Other SNMP Trap ID: 50 CIM Prefix: PLAT CIM ID: 0523 User Action: Information only; no action is required • FQXSPUP0002I: A firmware or software change occurred on system [ComputerSystemElementName]. This message is for the use case when an implementation has detected that the Firmware or Software Changed.
  • Page 139 3. If problem persists, collect Service Data log. 4. Contact Lenovo Support. • FQXSPUP4001I: Flash of [arg1] from [arg2] succeeded for user [arg3] . This message is for the use case where a user has successfully flashed the firmware component (MC Main Application, MC Boot ROM, BIOS, Diagnostics, System Power Backplane, Remote Expansion Enclosure Power Backplane, Integrated System Management).
  • Page 140 4. If problem persists, collect Service Data log. 5. Contact Lenovo Support. • FQXSPUP4004I: XCC firmware mismatch between nodes/servers [arg1] and [arg2]. Please attempt to flash the XCC firmware to the same level on all nodes/servers. A mismatch of XCC firmware has been detected between nodes/servers...
  • Page 141 CIM Prefix: IMM CIM ID: 0281 User Action: Information only; no action is required. • FQXSPWD0000I: Watchdog Timer expired for [WatchdogElementName]. This message is for the use case when an implementation has detected a Watchdog Timer Expired. Severity: Info Serviceable: No Automatically notify Support: No Alert Category: System - Other SNMP Trap ID:...
  • Page 142 Automatically notify Support: No Alert Category: System - Other SNMP Trap ID: CIM Prefix: PLAT CIM ID: 0374 User Action: Information only; no action is required • FQXSPWD0004I: Watchdog Timer interrupt occurred for [WatchdogElementName]. This message is for the use case when an implementation has detected a Watchdog Timer interrupt occurred.
  • Page 143: Chapter 3. Uefi Events

    UEFI error messages can be generated when the server starts up (POST) or while the server is running. UEFI error messages are logged in the Lenovo XClarity Controller event log in the server. For each event code, the following fields are displayed: Event identifier An identifier that uniquely identifies an event.
  • Page 144 Table 3. Events organized by severity (continued) Message String Severity Event ID FQXSFMA0001I DIMM [arg1] Disable has been recovered. [arg2] Informational The uncorrectable memory error state has been cleared. Informational FQXSFMA0002I FQXSFMA0006I [arg1] DIMM [arg2] has been detected, the DIMM serial number is Informational [arg3].
  • Page 145 Table 3. Events organized by severity (continued) Message String Severity Event ID FQXSFPU4059I User requested to skip freezing lock of AHCI-attached SATA drives. Informational System UEFI accepted the request and will execute priot to OS boot. FQXSFPU4060I Skipped freezing lock of AHCI-attached SATA drives. Informational FQXSFPU4061I Restored default locking behavior of AHCI-attached SATA drives.
  • Page 146 Table 3. Events organized by severity (continued) Message String Severity Event ID FQXSFIO0025I An error has been detected by the IIO on processor [arg1]. The index Warning of the IIO stack is [arg2]. The type of IIO Internal Error is [arg3]. Please check error logs for additional downstream device error data.
  • Page 147 Table 3. Events organized by severity (continued) Message String Severity Event ID FQXSFMA0053G An uncorrected memory error has been recovered by mirror on DIMM Warning [arg1] at address [arg2].[arg3] FQXSFMA0054G Mirror failover operation was successful. DIMM [arg1] has failed over Warning to the mirrored DIMM [arg2].[arg3] FQXSFMA0054M...
  • Page 148 Table 3. Events organized by severity (continued) Message String Severity Event ID FQXSFDD0004M DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required Error Controller. FQXSFIO0005M An intra-board UPI failure has been detected on the link between Error processor [arg1] port [arg2] and processor [arg3] port [arg4]. FQXSFIO0006M An inter-board UPI failure has been detected on the link between Error...
  • Page 149 Table 3. Events organized by severity (continued) Message String Severity Event ID FQXSFMA0010K Invalid memory configuration for Sparing Mode. Please correct Error memory configuration. [arg1] FQXSFMA0023M Error has occurred in NVDIMM flash. NVDIMM backup/restore may Error not operate correctly. [arg1] FQXSFMA0024M Error has occurred in NVDIMM Supercap.
  • Page 150: List Of Uefi Events

    2. Search for the driver menu from System Settings and change settings appropriately. 3. Save settings and restart the system. 4. If the problem persists, collect Service Data logs. 5. Contact Lenovo Support. • FQXSFDD0002M: DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller. Severity: Warning...
  • Page 151 Complete the following steps: 1. Reboot the system. 2. Reflash the adapter firmware. 3. If the problem persists, collect Service Data logs. 4. Contact Lenovo Support. • FQXSFDD0003I: DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller. Severity: Warning User Action: Complete the following steps: 1.
  • Page 152 User Action: Complete the following steps: 1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to this error. 2. A/C cycle the system. 3. If the problem persists, collect Service Data logs. 4. Contact Lenovo Support.
  • Page 153 Severity: Error User Action: Complete the following steps: 1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error. 2. If the problem persists, collect Service Data logs. 3. Contact Lenovo Support. • FQXSFIO0007M: An error has been detected by the IIO on Bus [arg1]. The value of Global Fatal Error Status register is [arg2].
  • Page 154 1. Check Lenovo support site for an applicable device driver, firmware update, version of service information for this product or other information that applies to this error. Load new device driver and any required firmware updates. 2. If this device and/or any attached cables were recently installed, moved, serviced or upgraded.
  • Page 155 1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat adapter and any attached cables. 2. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware update that applies to this error.(NOTE: It may be necessary to disable unused option ROMs from UEFI F1 setup, OneCLI utility, or using adapter manufacturer utilities so that adapter firmware can be updated.)
  • Page 156 1. Check the log for a separate error related to an associated PCIe device and resolve that error. 2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or adapter that applies to this error.
  • Page 157 1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve that error. 2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or adapter that applies to this error.
  • Page 158 Severity: Warning User Action: Complete the following steps: 1. Check Lenovo support site for an applicable service bulletin or firmware update for the system or adapter that applies to this error. 2. If the problem persists, collect Service Data logs.
  • Page 159 1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve that error. 2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or adapter that applies to this error.
  • Page 160 1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event denoting detected change in DIMM population that could be related to this problem.) 2. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error.
  • Page 161 6. Reflash UEFI firmware. 7. If the problem persists, collect Service Data logs. 8. Contact Lenovo Support. • FQXSFMA0006I: [arg1] DIMM [arg2] has been detected, the DIMM serial number is [arg3]. Severity: Info User Action: Complete the following steps: 1. If this information event is logged in the XCC event log, the server does not have qualified memory installed.
  • Page 162 5. Contact Lenovo Support. • FQXSFMA0009I: Invalid memory configuration for Mirror Mode has been recovered. [arg1] Severity: Info User Action: Information only; no action is required. • FQXSFMA0009K: Invalid memory configuration for Mirror Mode. Please correct memory configuration. [arg1] Severity: Error...
  • Page 163 DIMM connector on that memory channel. 2. If no problem is observed on the BBU connectors or the problem persists, Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error.
  • Page 164 BBU connector on that memory channel. 2. If no problem is observed on the BBU connectors or the problem persists, Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error.
  • Page 165 2. Boot to F1 setup and enable the DIMM. Reboot the system. 3. Update UEFI firmware to the latest version. 4. If the problem persists, collect Service Data logs. 5. Contact Lenovo Support. • FQXSFMA0028K: Memory Capacity exceeds CPU limit. [arg1] Severity: Error...
  • Page 166 2. Back up data. 3. Check if the PMEM meets warranty terms. a. If the PMEM meets the warranty terms, contact Lenovo Support for PMEM replacement. b. If the PMEM does not meet the warranty terms, order a new comparable PMEM through an authorized Lenovo reseller.
  • Page 167 3. This error message will provide the UID of the missing PMEM, 4. Use Lenovo Service Client or contact Lenovo Support to parse log to get correct location for PMEM Find the missing PMEM and install it in the correct location.
  • Page 168 5. If an error occurs, follow steps 1 and 4 to get details on new error message. 6. If the problem persists, collect Service Data logs. 7. Contact Lenovo Support. • FQXSFMA0037G: Intel Optane PMEM interleave set (DIMM [arg1]) is migrated from another system (Platform ID: [arg2]), these migrated PMEMs are not supported nor warranted in this system.
  • Page 169 4. If the issue is not resolved then contact Lenovo Support. • FQXSFMA0040K: Invalid Intel Optane PMEM configuration detected. Please verify PMEM configuration is valid. Severity: Warning User Action: Complete the following steps: 1. Check system spec and follow the rules for populating PMEM in correct order.
  • Page 170 DIMM population that could be related to this problem) 3. Restore A/C power and power on the system. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error.
  • Page 171 3. Reseat the failing DIMM identified by LightPath and/or event log entry 4. Restore A/C power and power on the system. 5. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error.
  • Page 172 Severity: Error User Action: Complete the following steps: 1. Check Lenovo support site for a firmware update required for this processor and install that update, if applicable. 2. If the problem persists, collect Service Data logs. 3. Contact Lenovo Support.
  • Page 173 2. Check Lenovo support site for a firmware update required for this Processor and install that update, if applicable. 3. If the problem persists, collect Service Data logs. 4. Contact Lenovo Support. • FQXSFPU0003K: A processor mismatch has been detected between one or more processors in the system.
  • Page 174 1. Verify that matching processors are installed in the correct processor sockets. Correct any mismatch issues found. 2. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error. 3. If the problem persists, collect Service Data logs.
  • Page 175 1. Verify that matching processors are installed in the correct processor sockets. Correct any mismatch found. 2. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error. 3. If the problem persists, collect Service Data logs.
  • Page 176 1. Verify that matching processors are installed in the correct processor sockets. Correct any mismatch found. 2. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error. 3. If the problem persists, collect Service Data logs.
  • Page 177 Severity: Error User Action: Complete the following steps: 1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to this error. 2. Reboot the system. 3. If the problem persists, collect Service Data logs.
  • Page 178 Severity: Error User Action: Complete the following steps: 1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error. 2. Reflash UEFI image. 3. Undo recent system changes (settings or devices added). Verify that the system boots. Then, re- install options one at a time to locate the problem.
  • Page 179 3. Undo recent system changes (settings or devices added). Verify that the system boots. Then, re- install options one at a time to locate the problem. 4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error. Update UEFI firmware if applicable.
  • Page 180 1. Perform a virtual reseat or AC cycle the server. 2. If the problem returns Collect Service Data log. 3. Contact Lenovo Support. • FQXSFPU4033F: TPM Firmware recovery is in progress. Please DO NOT power off or reset system. Severity: Warning User Action: Information only;...
  • Page 181 Information only; no action is required. • FQXSFPU4051G: Undefined TPM_POLICY found Severity: Warning User Action: Complete the following steps: 1. Reboot the system. 2. If the problem persists, collect Service Data logs. 3. Contact Lenovo Support. Chapter 3 UEFI events...
  • Page 182 User Action: Complete the following steps: 1. Reboot the system. 2. If the problem persists, collect Service Data logs. 3. Contact Lenovo Support. • FQXSFPU4053G: System TPM_POLICY does not match the planar. Severity: Warning User Action: Complete the following steps: 1.
  • Page 183 User Action: Information only; no action is required. • FQXSFPU4059I: User requested to skip freezing lock of AHCI-attached SATA drives. System UEFI accepted the request and will execute priot to OS boot. Severity: Info User Action: Complete the following steps: 1.
  • Page 184 1. If the CMOS clear was user initiated this event can be safely ignored and no further action is required. 2. If the system was recently installed, moved, or serviced, make sure the battery is properly seated. 3. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error.
  • Page 185 4. Reflash XCC Firmware. 5. If the problem persists, collect Service Data logs. 6. Contact Lenovo Support. • FQXSFSM0007I: The XCC System Event log (SEL) is full. Severity: Info User Action: Complete the following steps: 1. Use BMC Web Interface to clear event logs.
  • Page 186 3. Connect AC power to the system. 4. Power on system and retry. 5. If the problem persists, collect Service Data logs. 6. Contact Lenovo Support. • FQXSFTR0001L: An invalid date and time have been detected. Severity: Warning User Action: Complete the following steps: 1.
  • Page 187: Chapter 4. Xclarity Provisioning Manager Events

    Chapter 4. XClarity Provisioning Manager events The following events can be generated by the Lenovo XClarity Provisioning Manager. For each event code, the following fields are displayed: Event identifier An identifier that uniquely identifies an event. Event description The logged message string that appears for an event.
  • Page 188 Table 4. Events organized by severity (continued) Message String Severity Event ID FQXPMEM0004I Launching diagnostic program Informational FQXPMEM0005I boot diagnostic program success Informational FQXPMER0002I Clearing RAID configuration and internal storage Informational FQXPMER0003I RAID configuration cleared successfully Informational FQXPMER0004I Internal storage drives erased successfully Informational FQXPMER0005I All system logs cleared successfully...
  • Page 189 Table 4. Events organized by severity (continued) Message String Severity Event ID FQXPMOS0002K Failed to read Deployment Manager Signature from USB. Warning FQXPMOS0003K Failed to copy Windows boot files to target Warning FQXPMOS0004K BMC Communication Failed: EMMC2USB Mount Failure. Warning Warning FQXPMOS0005K BMC communication failed: DRIVER Mount Failure.
  • Page 190: List Of Xclarity Provisioning Manager Events

    Failed to execute reboot BMC command Error List of XClarity Provisioning Manager events This section lists all messages that can be sent from the Lenovo XClarity Provisioning Manager. • FQXPMCL0001K: Bootx64.efi is not found. Failed to Boot OS. Severity: Warning User Action: 1.
  • Page 191 3. Reboot system and retry OS booting. 4. Perform AC reset or virtual reseat. Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 5.
  • Page 192 • FQXPMCL0006K: Failed to export raid config. Severity: Warning User Action: 1. Check the following Lenovo support site for information on supported RAID adapters. http://www. lenovo.com/us/en/serverproven/index.shtml 2. Ensure RAID adapter, LXPM, and UEFI firmware are at the latest levels. 3. Ensure the state of the RAID adapter and disk drives are normal.
  • Page 193 6. Reboot the machine and retry the import of the RAID configuration. 7. If the problem persists, contact technical support. • FQXPMCL0008I: Export uefi settings successfully. Severity: Info User Action: Information only; no action is required. • FQXPMCL0008K: Failed to export uefi settings. Severity: Warning User Action: 1.
  • Page 194 3. Retry the export of BMC setting. 4. If the problem persists, contact technical support. • FQXPMCL0011I: Import bmc settings successfully. Severity: Info User Action: Information only; no action is required. • FQXPMCL0011K: Failed import bmc settings. Severity: Warning User Action: 1.
  • Page 195 Information only; no action is required. • FQXPMEM0005I: boot diagnostic program success Severity: Info User Action: Information only; no action is required. • FQXPMEM0006M: Unable to locate diagnostic firmware image Severity: Error User Action: 1. Restart BMC via supported method and reboot the system. 2.
  • Page 196 Severity: Error User Action: 1. Restart the system and retry the operation again. 2. If the problem persists, contact technical support. • FQXPMER0003I: RAID configuration cleared successfully Severity: Info User Action: Information only; no action is required. • FQXPMER0003M: Failed to erase internal storage drives Severity: Error User Action: 1.
  • Page 197 3. If the problem persists, contact technical support. • FQXPMER0006I: UEFI factory default settings loaded successfully Severity: Info User Action: Information only; no action is required. • FQXPMER0006M: Failed to load XCC factory default settings Severity: Error User Action: 1. Restart BMC via supported method and reboot the system. 2.
  • Page 198 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 5. If the problem persists, contact technical support. • FQXPMOS0002K: Failed to read Deployment Manager Signature from USB. Severity: Warning User Action: 1.
  • Page 199 User Action: 1. Ensure proper operation of the virtual USB connection. 2. Restart BMC via supported method and reboot the system. 3. Reflash BMC firmware. 4. Retry OS deployment. 5. Perform AC reset or virtual reseat. Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC.
  • Page 200 • FQXPMOS0009K: Current System Boot Mode is Legacy. LXPM OS installation only support UEFI Mode. Severity: Warning User Action: 1. Change boot mode to UEFI mode 2. Retry OS deployment. • FQXPMOS0028I: [arg1] OS installed Severity: Info User Action: Information only; no action is required. •...
  • Page 201 User Action: 1. Remove A/C from the server and reseat all drives, backplanes, RAID adapters, expanders (if any), and cables. 2. Ensure device firmware is at the latest level. 3. Retry the test. 4. If the problem persists, contact technical support. •...
  • Page 202 Severity: Error User Action: 1. Do one of the following: – If the affected drive(s) are detected by the system, update the disk drive firmware and reboot the server. – If the affected drive(s) are not detected by the system or failing to respond: a.
  • Page 203 User Action: 1. Check the following Lenovo support site for information on supported RAID adapters. http://www. lenovo.com/us/en/serverproven/index.shtml 2. Ensure RAID adapter, LXPM, and UEFI firmware are at the latest levels. 3. If the problem persists, contact technical support. • FQXPMSR0011K: Failed to change disk drives' state.
  • Page 204 3. Verify proper physical connection of the disk drive, SAS expander (if applicable)and RAID adapter. 4. Reboot the machine and retry to remove the existing virtual disk. 5. If the problem persists, contact technical support. • FQXPMSR0032I: Removed existing virtual disk successfully. Severity: Info User Action: Information only;...
  • Page 205 Severity: Warning User Action: 1. Restart BMC via supported method and reboot the system. 2. Reflash BMC firmware. 3. Perform AC reset or virtual reseat. Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC.
  • Page 206 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 4. If the problem persists, try a different Lenovo tool to perform the update (eg. XClarity Administrator, XClarity Controller, or XClarity Essential OneCLI).
  • Page 207 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 6. If the problem persists, try a different Lenovo tool to perform the update (eg. XClarity Administrator, XClarity Controller, or XClarity Essential OneCLI).
  • Page 208 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 4. If the problem persists, try a different Lenovo tool to perform the update (eg. XClarity Administrator, XClarity Controller, or XClarity Essential OneCLI).
  • Page 209 Note: When performing AC reset, after powering off AC, wait several seconds before powering on AC. After AC power is restored, power on the host system. 4. If the problem persists, contact technical support. • FQXPMVD0001H: Failed to get VPD data. Severity: Warning User Action: 1.
  • Page 210 ThinkSystem SR850 V3 Messages and Codes Reference...
  • Page 211: Appendix A. Getting Help And Technical Assistance

    Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about Lenovo products, you will find a wide variety of sources available from Lenovo to assist you. On the World Wide Web, up-to-date information about Lenovo systems, optional devices, services, and support are available at: http://datacentersupport.lenovo.com...
  • Page 212: Collecting Service Data

    Collecting service data To clearly identify the root cause of a server issue or at the request of Lenovo Support, you might need collect service data that can be used for further analysis. Service data includes information such as event logs and hardware inventory.
  • Page 213: Contacting Support

    Support when certain serviceable events occur in Lenovo XClarity Administrator and the managed endpoints. You can choose to send diagnostic files to Lenovo Support using Call Home or to another service provider using SFTP. You can also manually collect diagnostic files, open a problem record, and send diagnostic files to the Lenovo Support.
  • Page 214 ThinkSystem SR850 V3 Messages and Codes Reference...

This manual is also suitable for:

Thinksystem sr850 v37d977d98

Table of Contents