Technical Specifications - Airstream EXPERT 2V2SA User Manual

Table of Contents

Advertisement

EXPERT 2V2SA
14.

TECHNICAL SPECIFICATIONS

Supply: ......................115/230 VAC (-18%, +8%), 50/ 60Hz, overload and overvoltage protec-
Alarm: .......................ON-OFF output, 30VDC, 24VAC.
Temperature Probes ......Low voltage ( < 5V), isolated from the supply. Operating range: -40.0° to
Rel. Humidity Input: ......4 to 20mA current loop
Static Pressure Input: ....4 to 20mA current loop
Water Meter Input: .......Input pulse width > 12ms.
0-10V Output: .............30mA max
Stage 1: ....................Variable output, 50/60Hz, 115VAC 1/2HP (373W), 230VAC 1.5HP
Stage 2: ....................Variable output, 50/60Hz, 115VAC 1/2HP (373W), 230VAC 1.5HP
Stage 3: .....................ON/OFF output, 50/60Hz, 115VAC 1/4HP (187W), 230VAC 1/2HP (373W),
Stage 4: ......................ON/OFF output, 50/60Hz, 115VAC 1/4HP (187W), 230VAC 1/2HP (373W),
Actuator (winch): ......... Open/Close output, 50/60Hz, 115VAC (0.17HP 124W), 230VAC (0.5HP
Enclosure: .................ABS, moisture and dust-tight.
The room temperature where the controller is located must always remain between 32° and
104°F (0 and 40°C). For indoor use only !
tion fuse F1-1A fast blow.
120.0°F (-40.0° to 48.9°C). Accuracy: 1.8°F (1°C) between 41° and
95°F (5° and 35°C).
(1120W), 10 Amp Max. Fuse F2-15A slow blow.
(1120W), 10 Amp Max. Fuse F3-15A slow blow.
10 A Res. Max, 30VDC 5A Ind. Heating or cooling. Fuse F6-15A slow blow.
10 A Res. Max, 30VDC 5A Ind. Heating or cooling. Fuse F5-15A slow blow.
373W), 30 VDC 5A Ind. Fuse F4-5A slow blow.
EXPERT 2V2SA, rev. 10
53